Mounting With Quickfasten - SIKA VVX Série Notice D'utilisation

Masquer les pouces Voir aussi pour VVX Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation

3.2 Mounting with QuickFasten

IMPORTANT
 Observe the mounting dimensions of the VVX
 Observe the dimensions of the inlet
 Use only suitable O-rings
 Observe the flow direction indicated on the device
 Select an appropriate location for installation ( 3 "Installation").
To ensure the best possible measuring accuracy, a vertical installation position with in-
creasing flow is preferable (no collecting of dirt deposits).
 Install the appropriate QuickFasten connections (inlet and outlet) at the installation loca-
tion.
Mount the O-rings at the VVX and at the inlet.
Put the VVX on the inlet.
Ensure that the O-ring won't get damaged.
Slide the clip over the connection until it snaps into
place.
Put the outlet on the VVX.
Ensure that the O-ring won't get damaged.
Slide the clip over the connection until it snaps into
place.
IMPORTANT
The clip must snap properly.
The webs of the VVX and the inlet or outlet must be lo-
cated in the slots of the clip.
- 26 -
and outlet
of the right size (25.7 x 3.5).
( p. 35).
( p. 36).
.
© SIKA • Ba_VVX • 09/2021
VVX

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vvx15Vvx20Vvx25Vvx32Vvx40

Table des Matières