Installation
3.2 Mounting with QuickFasten
IMPORTANT
Observe the mounting dimensions of the VVX
Observe the dimensions of the inlet
Use only suitable O-rings
Observe the flow direction indicated on the device
Select an appropriate location for installation ( 3 "Installation").
To ensure the best possible measuring accuracy, a vertical installation position with in-
creasing flow is preferable (no collecting of dirt deposits).
Install the appropriate QuickFasten connections (inlet and outlet) at the installation loca-
tion.
Mount the O-rings at the VVX and at the inlet.
Put the VVX on the inlet.
Ensure that the O-ring won't get damaged.
Slide the clip over the connection until it snaps into
place.
Put the outlet on the VVX.
Ensure that the O-ring won't get damaged.
Slide the clip over the connection until it snaps into
place.
IMPORTANT
The clip must snap properly.
The webs of the VVX and the inlet or outlet must be lo-
cated in the slots of the clip.
- 26 -