10. Installation
 Mark the positions of the 4 holes.
 Drill the Ø 8 mm holes. Insert suitable
dowels.
 Bolt or screw the air distributor to the
wall/ceiling/bracket using suitable mounting
material to be supplied by the customer.
i
Make sure the installation doesn't
cause any distortion.
 Insert the duct system flexible ducts into
the housing as far as they will go (audible
click-in sound, 3 times).
Sealing integrity is not gua-
NOTICE
ranteed if the ventilation ducts
are twisted when installed.
 Insert the duct system flexible
ducts vertically into the
distributor as far as they will
go (audible click-in sound,
3 times).
 In the case of bent flexible
ducts, install a mounting clip
near to the distributor. Only
bend the flexible duct after
the mounting clip.
 Lay the flexible duct in the
mounting clip and fix it in
place.
 Close off non-used air distributor openings
with the sealing plugs [6] supplied.
 Locate the folded spiral-seams duct
Ø 160 mm on the plug connector [2].
11. Maintenance
Clean the air distributor and duct branches
annually. Use the cleaning kit for the ducts.
12. Disposal
Dispose of the air distributor once it has
reached the end of its working life according
to the regulations valid where you are.