Specifications

Product Specifications

Model
Typical Application:
Capacities:
Heads:
Electrical:
Motor:
Intermittent Liquid Temperature:
Minimum Recommended Sump Diameter:
Automatic Operation:
Materials of Construction:
Impeller:
Discharge Size:
Solids Handling:
Power Cord:
Performance Curve
40
30
20
10
0
32
MSK75
up to 147 GPM (556 LPM)
up to 34 ft (10.3 m)
208V 1ø 10.4 FLA, 60Hz;
230V, 1ø, 9 FLA, 60Hz;
230V, 3ø, 3.5 FLA, 60Hz;
460V, 3ø, 1.8 FLA, 60Hz;
575V, 3ø, 1.44 FLA, 60Hz
3/4 HP (with start capacitor, single phase), 1750 RPM
1 HP
3/4 HP
96
64
128
CAPACITY-U.S. G.P.M.
Sewage, effluent, dewatering
140°F (60°C)
Simplex = 24" (609.6 mm); Duplex = 36" (914.4 mm)
No Switch Standard (Manual) (Wide Angle Tethered Optional)
Class 30 cast iron
Class 30 Cast Iron, Two Vane
2" NPT (5.08 cm) standard, 3" NPT (7.62 cm) optional
2" (50.8 mm)
20' STW-A
160
192
MSK100
up to 160 GPM (606 LPM)
up to 38 ft (11.6 m)
208V, 1ø, 11.5 FLA, 60Hz;
230V, 1ø, 10 FLA, 60Hz;
230V, 3ø, 4.4 FLA, 60Hz;
460V, 3ø, 2.2 FLA, 60Hz;
575V, 3ø, 1.7 FLA, 60Hz
1 HP (with start capacitor, single phase), 1750 RPM