Télécharger Imprimer la page

Silverline 672976 Mode D'emploi page 8

Masquer les pouces Voir aussi pour 672976:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
GB
Troubleshooting
Problem
No function when Throttle Trigger
(4) is operated. Oscillating
Spindle (1) rotates freely
Oscillating Spindle (1)
performance is restricted, yet air
flows freely from the tool
Seized Oscillating Spindle (1)
Sander will not turn off when
Throttle Trigger (4) is released
8
Possible Cause
Air supply issue
Defective Throttle Trigger or throttle components
Internal vane seized
Broken internal vane
Defective internal Throttle Trigger components
Solution
Check all connections between compressor and tool, and ensure the
operating pressure is set correctly
In the event the internal throttle mechanism becomes jammed. Check for
dirt within the Air Inlet (6) and remove. Pour a small amount of air tool
oil (included) into the Air Inlet, reconnect the air supply and operate the
Throttle Trigger in small bursts. If the tool still ceases to function, return
to an authorised Silverline service centre
Disconnect the air supply. Pour a small amount of air tool oil (included)
into the Air Inlet (6), reconnect the air supply and operate the Throttle
Trigger in small bursts. Periodically tap the Spindle Housing using a
rubber mallet (not included). If the tool still ceases to function, return to
an authorised Silverline service centre
Return to an authorised Silverline service centre
Return to an authorised Silverline service centre

Publicité

loading