4.4.1 ON/OFF Boost
Setup Operation Boost
The BOOST function enables a faster charge of the batteries. This function is timed controlled and is
automatically switched off when the battery is fully charged : BOOST stops when batteries current < 20% of
charger rated current. BOOST function can also be disabled by either a DIP switch (E) inside the battery
charger or the BOOST press-button into Operation menu.
4.4.2 Charge ON/OFF
(not available on models YPO 12V-16A, 12V-25A and 24V-12A)
Setup Operation Charge
Indication if charge is ON or OFF
4.4.3 Night mode (only available for YPO 24V-30A and 12V-60A)
Setup Operation Night mode
4.4.4 Current limit
Setup Operation Current limit
The remote display has the ability to limit the total output battery charger current from 100% to 30% rated
output current. When activated, this limits runs during 8 hours before coming back to rated value.
The night mode ensures quiet
operation by stopping the fan and
smoothing the charge. It
automatically limits the total output
power according to the internal
ambient temperature.
When activated, Night mode
1
operation is limited to 8 hours.
1 : Night mode under operation
This function enables the user :
-
To lower the charge current if required ;
-
To control the input power consumption
of the battery charger in case of dips or
overcurrent nuisance tripping on AC
network due to an excessive consumption
on the boat overall electrical network.
1
1 : Current limit under operation