Electrical connection
DE05101, DE06101, DE06111, DE08101
and DE08111 (fixed electrical connection)
Connect the appliance on the terminal strip in
■
accordance with the connection schematic.
Put on the housing cover and push it onto the
■
rear wall of the appliance so that the upper and
lower latches engage.
DE04101 and DE10104
Replacing the Power Supply Cord:
The power supply cord must be replaced by our
■
customer service only in order to avoid a hazard.
The mains plug must be pulled before replacing.
DE 04101
DE 10104
L
N
PE
X
1
F
1
E
1
en
For all appliances
Vent the continuous-flow heater: Fully open
■
the warm water tap and flush out the appliance
for about 1 minute (G), until bubbles no longer
emerge.
G
DE 05101
DE 06101
DE 08101
L
N
PE
X
1
F
1
E
1
1 min
DE 06111
DE 08111
F
2
E
2