6
8. TECHNICAL SPECIFICATIONS
Input data
Frecuency range
Probe length
probe diameter
Max. pressure on sensing surface
Gap / installation distance
Mechanical connection
Type of installation
Torque value
Housing material
seal
Output data
Variants
Types
Switching capacity
Direction of rotation
Signal level
Ambient conditions
Operating temperature range
Media resistance of housing
- Zeichen
Vibration resistance to
EN 60068-2-64
Shock resistance: according to
EN 60068-2-27 / -29
Protection class to EN 60529
Other data
Electrical connection
Supply voltage
Residual ripple of supply voltage
Current consumption
Average life time
Weight
Note
Reverse polarity protection of the supply voltage and load short circuit protection (max. 50 mA) are provided.
All details are subject to technical modifications.
Stand: 14.03.2013
0.1 .. 20,000 Hz
30; 35; 45 mm
15 / 12 mm
15 bar dynamic
Probe length: 30 mm
Module 1:
Module 1.25:
Module 1.5:
Module 2:
Module 2.5:
Flange, single, asymmetrical, cable outlet at 90°(30 mm)
/ axial (35 / 45 mm)
Dependent on direction
(with asymmetrical flange)
10 Nm
Brass
FPM
2-channel frequency
(90° / 270° phase shift for module 2)
2 NPN frequency outputs
≤ 50 mA
≥ 10 kΩ ohmic resistance
≤ 200 nF capacitive resistance
Flange on left, gear turns to right:
channel A lagging; channel B leading
LOW: ≤ 0.5 V
-40 .. +140 °C
(-40 .. +160° C for max. 500 operating hours)
Salt water; various hydraulic oils; diesel oils; cleaning
agent; salt spray
DIN EN 60947-5-2
30 g, 10 .. 500 Hz, 100 min in each direction
50 g, 11 ms, 3x in each direction
100 g, 6 ms, 3x in each direction
IP 67; IP 69K
Free cable end, 4-core, 1m cable length
7 .. 30 V DC
≤ 5 %
< 30 mA at 30 V DC
200,000 h (MTTF)
~ 80 g
HYDAC ELECTRONIC GMBH
35 / 45 mm
0.2 .. 1.0 mm
0.2 .. 1.3 mm
0.2 .. 1.5 mm
0.2 .. 1.8 mm
0.2 .. 1.7 mm
0.2 .. 2.0 mm
0.2 .. 2.2 mm
0.2 .. 2.5 mm
0.2 .. 3.2 mm
0.2 .. 3.5 mm
/
HIGH: +U
B
Mat. Nr.: 669893 D/E/F
HSS 120