RAC 83/95
TOOL IDENTIFICATION
The riveting tool RAC 83/95 is identified from a marking that
shows company name and address of manufacturer, designation
of the tool, CE.
If any service is requested, please make reference to the data
shown on the marking.
Designation
of the tool
TECHNICAL DATA
• Working preessure .....................................................6 BAR
• Min. int. diam. of the compressed air
feeding hose ......................................... min. diam= 8 mm
• Air consumption per cycle .........................................2,2 Nl
• Maximum force ............................................. 6 BAR 5372 N
• Weight .................................................................. 1,500 Kg
• TWorking temperature .......................................- 5° / + 50°
• Root mean square in total acceleration frequency (Ac)
to which the arms are subjected. ........................... 3,3 m/s
• A-weighted emission sound pressure level ............. 84 dBA
• Peak C-weighted instantaneous sound pressure.. <130 dBC
• A-weighted sound power ......................................... 96 dBA
AIR FEED
The air feed must be free from foreign bodies and humidity
in order to protect the tool from premature wear and tear of
the components in movement, therefore we suggest to use a
lubrificator group for compressed air.
MAINTENACE AND CHANGE OF SIZE (fig. f1)
The extended utilization of the riveting tool can cause the slipping
of the clamps on the nail due to the deposited impurities.
For this reason, it is necessary to lubricate the clamps after
having cleaned them . However, if clamps are worn out and
as a consequence their working is jeopardized, replace them.
First remove the head which carries the nozzle (E), by means
of a standard spanner of 27 mm. Then, by using two standard
spanners of 15 mm and 16 mm, remove the chuck (F) and
extract the clamps (G).
When replacing the nozzle (A), we recommend to use a 12-
mm standard spanner and fit the removed nozzle in the proper
housing located on the bottom of your riveting tool, in order
to avoid losing the nozzle.