T E C H N I C A L D A T A L A V A
> Voltage:
> Power consumption:
> Surface temperature:
> Surface:
ARCUS infrared heating, round, RAL 9016 traffic white
LAVA
®
Type
LAVAARCUS-ST-400-W
Accessories
Type
eTWIST
eTOUCH-eco
eTOUCH wifi
eTOUCH mini
ET-14A
ET-111A
I N F O R M A T I O N O N E N E R G Y C O N S U M P T I O N
In combination with an eco-design compliant thermostat, the product specifications comply with EU directive regulations on the
environmentally friendly design of energy-related products (ErP).
Faults
Device does not heat:
› Has the fuse been triggered or is it defective?
› Is the external switch in the supply line switched off?
› Is the setpoint temperature of the room temperature con-
troller set lower than the actual temperature of the room?
D E V I C E R A T I N G P L A T E S
The rating plate contains the type-specific technical data. Depending on the arrangement (vertically or horizontally), the rating
plate of the device is placed at the top or on the left on the device.
LAVAARCUS-ST-400-W
400 W | IP 21
Landesstraße 16
230 V | 50 Hz
A-5302 Henndorf
6 kg
Made in Austria
Exemplary nameplate: nameplate LAVA
G E N E R A L W A R R A N T Y C O N D I T I O N S
Dear customer,
Please observe our general terms and conditions. Country-specific legal entitlements apply to warranty claims; please assert
such rights directly through your distributor.
ATTENTION: Many old electrical and electronic devices contain valuable materials. However, they can also contain harmful substances which
were required for their operation and safety. Such substances may damage the environment if disposed of in residual waste or handled incor-
rectly. Please help us to protect the environment! Do not place your old devices in the residual refuse. Dispose of your old device in accordance
with applicable local regulations. Properly dispose of packaging material, replaced parts and/or components.
RESERVATION: We reserve the right to make technical changes. Modifications, errors and misprints shall not constitute grounds for damages.
16
B A S I C - D M
®
230 V
400 W
Ceiling installation max. 120 °C
Wall installation max. 95 °C
Structured surface
Art. no.
Control system
40922
none
Art. no.
Description
40517
Switch mounted thermostat with control dial and app function via Bluetooth 4.2, 16 A, 5-28 °C, white
40511
Switch mounted thermostat with touch pad, 16 A, 5-35 °C, white
44722
Switch mounted thermostat with touch pad and Wi-Fi function, 16 A, 5-40 °C, white
39300
Switch mounted thermostat with white touch pad, 16 A, 5-40 °C
40595
Radio room thermostat, LCD display with clock and weekly program
36758
Wireless receiver with 10 A relay in wall-mounted housing
Do not cover!
Nicht abdecken!
ARCUS
®
> Colour:
> Device/installation depth: 60/80 mm
> IP rating:
> Connection cable:
> Warranty:
Output (W)
Diameter (mm)
400
Radiation heat too low:
› Is the distance between the radiation heater and the person
too large?
› Has the device size been selected too small?
› Are there objects placed between the radiation heater and
the person?
Traffic white RAL 9016
IP 21
1 m, 3 x 1.5 mm² without plug
5 years
Discount group: 018 | Delivery time: ex stock
Weight (kg)
745
6
Discount group: 007 | Delivery time: ex stock