8.4 - ALARMS SETTING
Overdosing alarm: For any kind of problems may occur in the plan (wrong calibration, dirty or broken probe,
etc.) if the pump doesn' t reach the Setpoint in OVER ALARM TIME, the pump stops the dosing. On the display Alarm
message will flash, Alarm Led will flash.
To enter in ALARM menu follow the procedure described in paragraph
7.1 - PUMP SETUP.
When ALARM menu is reached, press OK to enter in submenus
8.4.1 - Overdosing Alarm setting
On the display will appear OVER and time counter (h:min) will flash.
Press + and - to adjust the time, over which the pump will go in
alarm.
Press OK to confirm and to save data.
This will end the alarm setting.
Press ESC to return in measure mode.
8.5 - RESET PROCEDURE
The pump is equipped with a RESET procedure. It can be used any time the user has to reset calibration parameters.
• Turn off and turn on the pump
• Press once the OK button, it will appear SETPOINT menu
• Press at the same time button + and button - (user has15 seconds
to make this operation after pressed OK button).
• On the display will appear RESET
ATTENTION: RESET procedure must be performed within 15 seconds from the pump startup. Over this time
to use this procedure, user has to turn off and turn on the pump.
8.6 - STAND-BY PROCEDURE
When the pump is in functioning, press at the same time - e +, pump stop, in order to exit to this mode press - and + button.