EN
No
Parameter
Description
Adjustable from 15 to 120
0
Boost time
minutes in 15-minute
increments
Adjustable from 15 to 120
Programme P1
1
minutes in 15-minute
time
increments
Adjustable from 15 to 120
Programme P2
2
minutes in 15-minute
time
increments
Type of
Cannot be modified on this
3
programme
model
Setpoint tempera-
4
Not available on this model
ture calibration
Room temperature
5
Not available on this model
calibration
Type of energy
6
NEVER modify! *
source
7
Default display
Not available on this model
Reset to factory settings.
Version number
8
display and reset
The time will have to be
re-set.
Quitting parameter
End
Quit parameter setting menu
settings display
* The remote control parameters are set according to the power supply of your towel radiator (hot
water or electricity). We advise against modifying the default value.
36
Default setting
Setting
+
-
Press the
or
30 minutes
key
+
-
Press the
or
30 minutes
key
+
-
Press the
or
30 minutes
key
0
--
--
0
0
+
Press the
key
for 10 seconds
P2
Press
40005959
4. Maintenance and troubleshooting tips
4.1 Routine maintenance operations
High-quality materials and surface treatment protect your appliance against
corrosion and impacts.
To maximise the service life of your radiator, we recommend you take the
following precautions:
- Never use abrasive or corrosive products on the outer surfaces of the appliance
(except the electrical parts); use warm, soapy water.
- Use a soft, dry cloth without any solvents to clean the blower and the remote
control.
4.2 Cleaning the filter
With time, the dust build-up may cause the filter situated at the rear of the blower
to clog. After approximately 200 hours of blower operation, the FILTER alarm LED lights
up to indicate the need to clean the filter.
Regular filter cleaning is therefore necessary for the blower to function correctly
and efficiently.
Pull out the filter situated at the rear of the blower and wash it in warm water
(then leave to dry) or clean it with a vacuum cleaner. The blower stops operating to pro-
tect your appliance during this operation. The
Boost indicator continues to blink if the blower was running before removal of the filter.
After cleaning replace the filter in its housing, and lock it into position. The
dicator continues to blink. Press and hold Reset to complete the operation: the
dicator goes off and the boost restarts if the blower was running before removal of the
filter.
▼ ▼
40005959
and Filter indicators begin to blink. The
in-
in-
EN
37