Ecf-2 Zero Calibration; Ecf-3 Span Calibration; Counting Pieces Function; Piece Weight Setup - Gram CK 3 Série Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ECF-2 Zero Calibration

1. Press the
key to exit menu and back to weighing mode.
2. Press the
3. Calibration procedure completed and the scale will return back to
weighing mode automatically.

ECF-3 SPAN Calibration

1. Press the
key to exit menu and back to weighing mode.
2. Use 0 ~ 9 keys to enter the weight to be calibrated and confirm with
3. Place the required weight mass onto the scale and press the
4. Calibration procedure completed and the scale will return back to
weighing mode automatically.

COUNTING PIECES FUNCTION

Piece weight setup

Place the object on the weighing pan, use 0-9 number keys and decimal (.)
key to introduce the unit weight. Weight window displays the total weight,
piece weight windows shows unit weight and total count windows displays
the total pieces.
key to start and go to the ECF-2 mode, and press the
key to set the zero weight.
key to start and go to the ECF-3 mode, and press the
.
key.