Air supply connection
• For correct use of the pneumatic tool, always keep to a maximum pressure of 10 bars, as measured
at the tool inlet. Feed the pneumatic tool with clean, condensate-free air. Excessively high pressure
or humidity in supply air results in shorter life for the mechanical parts and may damage the tool.
USE
Start / Stop
To start the air gun, press the trigger and keep it pressed during the job to be performed. Releasing
the trigger will cause the pneumatic tool to stop quickly, thereby preventing grease from being let out.
When the gun stops, place it in a firm and safe position.
Cartridge installation/replacement
• Make sure that the gun is disconnected from the power supply.
• Release and remove the cartridge tube.
• Bring the (grease dispensing) plunger trigger to the end of the stroke.
• Fit the grease cartridge into the tube, removing the front part of the cartridge.
• Tighten the cartridge tube onto the gun head.
• Release the plunger trigger, and press the air valve, to let any air pockets out.
• Connect the gun to the power supply.
• Hold the gun firmly, press the trigger and proceed with grease dispensation; when the trigger
is released, grease dispensation will stop quickly.
• Replace the cartridge when exhausted, and remove any grease residues from the gun.
As grease is dispensed continuously during operation, be careful not to let too much grease out.
Grease feeding
• Make sure that the gun is disconnected from the power supply.
• Release and remove the cartridge tube.
• Bring the (grease dispensing) plunger trigger to the end of the stroke.
• Fill up the cartridge tube with grease.
• Tighten the cartridge tube onto the gun head.
• Release the plunger trigger, and press the air valve, to let any air pockets out.
• Connect the gun to the power supply.
• Hold the gun firmly, press the trigger and proceed with grease dispensation;
when the trigger is released, grease dispensation will stop quickly.
• Replace the cartridge when exhausted, and remove any grease residues from the gun.
As grease is dispensed continuously during operation, be careful not to let too much grease out.
Handle rotation
• Make sure that the gun is disconnected from the power supply.
• Slightly loosen the throttle screw.
• Orientate the handle to the most comfortable position.
• Lock the throttle screw.
• Connect the gun to the power supply.
Always disconnect the air supply before making adjustments or installing the cartridge. This precaution
will prevent the pneumatic tool from being accidentally started.