8. TROUBLESHOOTING

PROBLEM
SITUATION
1. Pilot lamp off
Key is in «ON»
position, engine
stopped
2. Starter motor not
Key in «START»
working
position and pilot lamp
on
Key in «START»
position and pilot lamp
flashing
3. Engine does not
Key in «START»
start
position
LIKELY CAUSE
Electronic card in safety alert,
due to:
– badly connected battery
– completely flat battery or eroded battery
plates
– battery terminals crossed
– fuse blown
– badly earthed
– electronic card wet
– earthed micro-switches
– insufficiently charged battery
– battery charger fuse blown
– badly earthed
– you are not ready for starting
– no fuel supply
– faulty ignition
SOLUTIONS
Put the key in the «OFF» position and look for
the cause of the problem:
– check connections
– recharge battery
– connect properly
– replace fuse (
6.3.4)
– check connections
– dry by air
– check connections
– recharge battery (if the problem continues,
consult a Licensed Service Centre)
– replace fuse (
6.3.4)
– check connections
– Check that the conditions allowing the start
are met (
5.3.7)
– check fuel level
– open fuel stop-cock (where fitted)
– check the wiring of the fuel open command
(where fitted)
– check fuel filter
– check that spark plugs caps are firmly fitted
– check that the electrodes are clean and have
the correct gap