3
Technical data
General data and operating conditions
Environmental conditions
Climate
Storage
Transport
Operation
Site altitude
Pollution
Vibration resistance
Transport
Operation
Mounting conditions
Mounting place
Mounting position
Free space
At the top/at the
bottom
On the sides
50
IEC/EN 60721−3−1
IEC/EN 60721−3−2
IEC/EN 60721−3−3
IEC/EN 60664−1
2
(9.81 m/s
= 1 g)
IEC/EN 60721−3−2
EN 61800−2
Germanischer Lloyd
IEC/EN 60068−2−6
l
1K3 (−25 ... +60 °C)
2K3 (−25 ... +70 °C)
3K3 (−10 ... +55 °C)
Current derating at +45 ... +55 °C:
Device size 1 ... 7: 2.5 %/°C
Device size 8S ... 10: 1 %/°C
0 ... 4000 m amsl
1000 ... 4000 m amsl: current derating of 5 %/1000 m
Pollution degree 2
2M2
2 ... 9 Hz: amplitude 3.5 mm
10 ... 200 Hz: acceleration resistant up to 10 m/s
200 ... 500 Hz: acceleration resistant up to 15 m/s
5 ... 13.2 Hz: amplitude ±1 mm
13.2 ... 100 Hz: acceleration resistant up to 0.7 g
10 ... 57 Hz: amplitude 0.075 mm
57 ... 150 Hz: acceleration resistant up to 10 m/s
In the control cabinet
Vertical
³ 80 mm / ³ 120 mm
Side−by−side mounting without
any clearance
2
2
2
Observe the device−related
notes on mounting.
EDK94ASH24 DE/EN/FR/ES/IT 5.0