NOTE: The maximum continuous load is
400 watts. Do not use the inverter with a
product that draws more than 400 watts,
as this may cause damage to the inverter
and the product.
6.7 Converter Shutdown Protection
The GREEN LED lights automatically
when the converter is turned on. The RED
LED will light and the coinverter will shut
down under the following conditions:
1. When the power input from the jump
starter's battery drops to approximately
10.5 volts, low battery shutdown
occurs and the inverter shuts off.
NOTE: At approximately 10.5 volts, the
inverter alarm will sound, indicating the
battery voltage is getting low. Solution:
Recharge the jump starter.

7. MAINTENANCE INSTRUCTIONS

7.1 After use and before performing
maintenance, unplug and disconnect
the jump starter.
7.2 Use a dry cloth to wipe all battery corrosion
and other dirt or oil from the battery clips,
cords and the jump starter case.

8. MOVING AND STORAGE INSTRUCTIONS

8.1 Store inside, in a cool, dry place.
8.2 Do not store the clips on the handle,
clipped together, on or around metal, or
clipped to cables. The clips on the jump
starter are live when the switch is in the
ON position and will produce arcing or
sparking if they come in contact with each
other. To prevent accidental arcing, always
place the switch in the OFF position and
keep the clips on the storage holders when
not using it to jump start a vehicle.
8.3 If the jump starter is moved around the
shop or transported to another location,
take care to avoid/prevent damage to the
cords, clips and jump starter. Failure to
do so could result in personal injury or
property damage.
IMPORTANT: Do not use and/or store the
jump starter in or on any area or surface
where damage could occur if the internal
battery should unexpectedly leak acid.
2. When the power input from the jump
starter's battery exceeds 15 volts, high
voltage overload protection occurs.
Solution: Reduce the voltage range of the
battery to between 12 volts and 14 volts.
3. The continuous load demand from the
equipment or device being operated
exceeds the inverter's 400 watt capacity.
Solution: Use a lower rated device.
4. The case temperature becomes hot
(exceeds 145°F). Solution: Allow the
inverter to cool. Do not block the cooling
slots or air flow over and through the
jump starter. Reduce the load on the
converter to the continuous rated output.
RESET: To reset after shutdown occurs,
turn the converter OFF. Check the source of
the problem and correct. Turn the converter
back ON.
7.3 Ensure that all of the jump starter
components are in place and in good
working condition.
7.4 All servicing should be performed by
qualified service personnel.
8.4 IMPORTANT:
• CHARGE IMMEDIATELY AFTER
PURCHASE
• KEEP FULLY CHARGED
Charge the jump starter's internal battery
immediately after purchase, after every
use and every 30 days.
All batteries are affected by temperature.
The ideal storage temperature is at
70°F. The internal battery will gradually
self-discharge (lose power) over time,
especially in warm environments. Leaving
the battery in a discharged state may
result in permanent battery damage. To
ensure satisfactory performance and
avoid permanent damage, charge the
internal battery every month.