Maintenance Instructions; Moving And Storage Instructions; Troubleshooting - DSR Industrial Série Guide D'utilisation

Masquer les pouces Voir aussi pour Industrial Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.
Multiply the results by 1.25 and you will have the total time needed, in hours, to bring
the battery to full charge.
4.
Add an additional hour for a deep-cycle battery.
Example:
Amp Hour Rating x % of charge needed x 1.25 = hours of charge
100 (AH Rating) x 0.50 (charge needed) x 1.25 = 3.125 hours
20 (Charge Rate Setting)
100 x 0.50 x 1.25 = 3.125
20
You would need to charge your 100-Ampere Hour Battery for a little more than 3 hours
at the 20-Amp charge rate using the above example.
12.

MAINTENANCE INSTRUCTIONS

12.1
After use and before performing maintenance, unplug and disconnect the battery
charger (see sections 6 and 7).
12.2
Use a dry cloth to wipe all battery corrosion and other dirt or oil from the battery
connector, cords, and the charger case.
12.3
Ensure that all of the charger components are in place and in good working condition.
12.4
Servicing does not require opening the unit, as there are no user-serviceable parts.
12.5
All other servicing should be performed by qualified service personnel.
13.

MOVING AND STORAGE INSTRUCTIONS

13.1
Store the charger unplugged, in an upright position. The cord will still conduct electricity
until it is unplugged from the outlet.
13.2
Store inside, in a cool, dry place.
13.3
If the charger is moved around the shop or transported to another location, take care to
avoid/prevent damage to the cords, connector and charger. Failure to do so could result
in personal injury or property damage.
14.

TROUBLESHOOTING

PROBLEM
The charger is making an
audible clicking sound.
Charge Rate Setting
POSSIBLE CAUSE
Circuit breaker is cycling.
Battery is defective.
Shorted battery cables or
connector.
Severely discharged battery,
but otherwise it is a good
battery.
Reverse connections at
battery.
The settings may be wrong.
Check the charger settings.
Have the battery checked.
Circuit breaker cycles when
current draw is too high.
Check for shorted cables or
cconnector and replace if
necessary.
The battery may not want to
accept a charge due to a run-
down state. Allow charging to
continue until battery has a
chance to recover sufficiently
to take a charge. If more than
20 minutes, stop charging and
have the battery checked.
Shut the charger off and
correct the lead connections.