Setup zone types
[#] + [60] + [xxx] + [y] + [z] + [#]
Setup specific phone numbers
[#] + [63] + start device ID + end
per alarm zone
device ID + [y] + [#]
[#] + [57] + [yy] + start time + end
Setup arming schedule
time + day number + [#]
Delete arming schedule
[#] + [57] + [yy] + [0] + [#]
Setup arming schedule with
[#] + [58] + [yy] + start device ID +
defense zones
end device ID + [#]
Setup control range for remote
[#] + [54] + [xxx] + start device ID +
control/control panel
end device ID + [#]
Setup audible feedback for
[#] + [55] + [xxx] + [y] + [#]
remote control/control panel
Query
To enter the query mode, press the query button on the control panel.
To carry out queries, press [#] + code + (parameters) + [#].
To exit the query mode, press [*] + [#].
Query
Stored phone number
Password
Arming delay time
Alarm delay time
Alarm sound duration
Control range for remote control/control
panel
Audible feedback for remote control/
control panel
Date and time
Arming schedule
Zone/device per arming schedule
Zone type and siren per zone/device
Status remote control by telephone
Phone numbers per zone/device
Volume audible feedback
Power-saving mode
Volume built-in siren
Display light flashing
Voice prompt on/off
Use of remote control for arming/disarming
Interference prompts
Control panel lock
Access log arming
Access log alarm
[xxx] = detector ID (001-120). [y] = zone type (1-8). [z] = 0 (siren off ) or 1 (siren on).
Zone types:
1.
Normal zone
2.
Partial-arm zone: Detectors in the zone can be deactivated by remote control. The
system is partially armed.
3.
Intelligent zone: A second trigger within 30 seconds after the first trigger will cause
an alarm.
4.
Emergency zone: Any trigger will result in an alarm, regardless of arming mode.
5.
Closed zone: A trigger will not result in an alarm, regardless of arming mode.
6.
Chime zone: Any trigger will result in a sound of the doorbell, regardless of arming
mode.
7.
Welcome zone: When armed, any trigger will result in an alarm. When disarmed, any
trigger will result in an audible welcome message.
8.
Help zone: Any trigger will result in an alarm and dialling of the three emergency
numbers with pre-recorded need-help message, regardless of arming mode.
[y] = phone number ID (1-9).
Example 1: "630010061234" = auto-dial phones 1-4 when zones 001-006 are triggered.
Example 2: "630200206" = auto-dial phone 6 when zone 020 is triggered.
[yy] = arming schedule (01-04).
Example 1: "58010700173012345" = arm on weekdays between 07:00 and 17:30.
Example 2: "5802180006005671" = arm from Friday to Monday between 18:00 and 06:00.
[yy] = arming schedule (01-04).
[yy] = arming schedule (01-04).
Example: "5801001003" = devices 001-003 follow arming schedule 01.
Default: Remote control and control panel control all zones.
[xxx] = [***] for control panel / [001-120] for remote control.
Example: "54001000010" = remote control 001 controls zones 0 to 10.
[y] = 0 (off ) or 1 (on).
[xxx] = [***] for control panel / [001-120] for remote control.
Example: "55***0" = no audible feedback when arming by control panel.
Command
Remarks
[#] + [3] + [y] + [#]
[y] = phone number ID (1-9).
[#] + [50] + [#]
[#] + [51] + [#]
[#] + [52] + [#]
[#] + [53] + [#]
[#] + [54] + [xxx] + [#]
[xxx] = [***] for control panel / [001-120] for remote control.
[#] + [55] + [xxx] + [#]
[xxx] = [***] for control panel / [001-120] for remote control.
[#] + [56] + [#]
[#] + [57] + [yy] + [#]
[yy] = arming schedule (01-04) / alarm clock status (05-06).
[#] + [58] + [yy] + [#]
[yy] = arming schedule (01-04).
[#] + [60] + [xxx] + [y] + [z] + [#]
[xxx] = device ID (001-120). [y] = zone type (1-8). [z] = 0 (siren off ) or 1 (siren on).
[#] + [62] + [#]
[#] + [63] + [xxx] + [#]
[xxx] = device ID (001-120).
[#] + [79] + [#]
[#] + [84] + [#]
[#] + [87] + [#]
[#] + [88] + [#]
[#] + [11] + [#]
[#] + [15] + [#]
[#] + [16] + [#]
[#] + [17] + [#]
[#] + [9901] + [#]
The result will be a sequence of codes:
[aa]: record number (max. 72 records). [bbbb]: month/day. [cccc]: hour/minute.
[dd]: YC = remote control / JP = control panel / DS = arming schedule.
[#] + [9900] + [#]
[ee]: YK = remote control / CF = disarm / BF = arm / 01 = first remote control.