Troubleshooting

With this converter, you have acquired a product that is reliable and operationally safe.
Nevertheless, problems or errors may occur.
For this reason we want to describe how to troubleshoot potential malfunctions:
Always follow the safety instructions!
Error
The converter cannot
be switched on.
Connected consumer devices
do not work.
The display (9) flashes.
Indicator (10) is lit normally.
The displays (9 and 10) flash.
The AC output is switched off.
Regularly check the technical safety of the device e.g. for damaged housing, connection lines, etc.
Any other repair work must always be carried out by a specialist familiar with the
hazards involved and with the relevant regulations. Unauthorized modifications
or repairs to the device invalidate the warranty/guarantee. Fuses are replace-
ment parts and not covered by the warranty!
34
Possible cause
Are the operating indicators (9 and 10) lit ?
Check the voltage supply.
Check the input fuse and connection cables for contact.
Is the converter overloaded?
Is voltage supply sufficient?
Check the technical data of the consumers.
The input voltage decreased.
Check the voltage source and recharge the battery as soon as
possible if required.
The converter is overloaded
Check the technical data of the consumers.
Deep discharge protection is active.
Check the voltage source and recharge the battery at once.
the converter switches on again automatically at a voltages of
12.5 V or 25 V.
The input voltage rose too far.
Switch off the converter and check the power source.