7. Possible Malfunctions

Problem
No cooling
Too high of a
temperature in
the device
Too low of a
temperature in
the device
Noise level too
high
- 30 -
Cause
• The plug is not connected to
the socket
• Damaged fuse
• Loss of electrical power
• Faulty thermostat
• Direct sunlight or located near
a heat source
• Improper air circulation in the
device.
• The door is improperly closed
or was left open too long
• The door seal is damaged
• The spacing between the
stored bottles is too small
or there are too many
bottles in the device
• Too low of a temperature
• Too high of a temperature
• The device is not standing on
a level surface
• The device touches walls or
other objects
Solution
• Connect the plug to the
socket
• Check the power supply
Check the device by
plugging it into another
socket
• Check the power supply
• Contact a salesperson
• Move the device away
from the heat source
• Ensure a sufficient
distance from walls and
other objects
• Close the door properly
and minimize the time of
opening the door
• Contact a salesperson
• Ensure the correct
distance between the
bottles, remove excess
• Adjust the thermostat
lower
• Adjust the thermostat
higher
• Set the device on a level
surface
• Ensure a sufficient
distance from walls or
other objects
.

Publicité