Connecting the fan to a hose and duct (FUA-3000/4700)
4.3

Electric connection

ATTENTION!
Electric connection to be executed in accordance
with local requirements. Ensure compliance with the
EMC regulatory arrangements.
WARNING!
Make sure that the fan is suitable for connection to
the local mains. Information about the connection
voltage and frequency can be found on the
identification plate. The cables must be connected in
conformance with the local rules and regulations
and can only be carried out by qualified and
authorised technicians.
The default setting for the 3~ fans is 400V. If another voltage
is used, the wiring must be changed according to the
instructions on the identification plate.
To connect the starting device, proceed as follows:
• Connect the fan to the chosen starting device according to
the information on the identification plate on the motor.
• Connect the starting device to the mains according to the
separately supplied electrical diagram.
• Check the direction of rotation of the motor. For this
purpose the fan contains an arrow indicating the prescribed
direction of rotation. The rotation is visible through the grid
of the motor.
• If necessary, invert the connection of the phases.
5

USE

Refer to the documentation supplied with the selected control
equipment how to control the fan.
6

MAINTENANCE

The fans require no specific maintenance.
7

TROUBLESHOOTING

If the product does not function (correctly), consult the
checklist below to see if you can remedy the error yourself.
Should this not be possible, contact your supplier.
WARNING!
Always switch off the machine and disconnect it
from the mains before carrying out the activities
below. First read the maintenance regulations at the
beginning of this manual.
0000100435/060614/A FUA-1300/1800/2100/3000/4700 (50Hz)
A
B
C
Symptom
Problem
Motor does not
Machine does
start.
not function.
Motor makes a
Machine does
humming
not function.
sound, but
does not run.
Motor stops
Machine does
automatically.
not function.
Poor suction.
Machine does
not function
properly.
Vibrations in
Machine not
the machine.
steady.
Possible cause
Solution
No mains
Check the mains
voltage.
voltage.
Mains cord
Repair or replace
defective.
mains cord.
Loose contacts.
Repair the
contacts.
Motor protection
Replace the
switch defective.
motor protection
switch.
Motor defective.
Repair or replace
motor.
Motor uses 2
Repair the phase
phases instead of
connection.
3 (three-phase
motor only).
Motor capacitor
Repair or replace
defective/not
the motor
connected (single
capacitor.
phase motor
only).
Motor protection
Let the machine
switch activated.
cool down for
some time.
Check setting of
motor protection
switch (MPS)
according to
electrical
diagram.
Motor defective.
Repair or replace
the motor.
Inverted
Change the
direction of
direction of
rotation of the
rotation.
motor (three-
phase motor
only).
Motor defective.
Repair or replace
the motor.
Extraction fan
Clean the
polluted.
extraction fan.
Outside air is
Check or replace
being extracted.
the sealing
material.
Imbalance in the
Clean the
extraction fan.
extraction fan.
EN - 8