Télécharger Imprimer la page

Astralpool OPTIMA PLUS Manuel D'installation page 10

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 40
Paragraph 8 – Delay calibration Setting
Programming
Delay Calib.
Paragraph 9 – Flow Calibration
Programming
PROG
-
-
Pump Calibration
0,23 cc/stroke
Pump Calibration
Manual
-
Pump Calibration
Automatic
-
EM00136408
-
Pump Calibration
+
cc/stroke
0,23
Automatic Cal.
Start 100 strok.
Automatic Cal.
Strokes
100
-
Automatic Cal.
+
ml
20
Used to set a pump operation delay after calibration of the probe
(Redox or pH).
The setting can be disabled (Off - factory default) or else can be set
to a delay time ranging from 1 to 60 minutes.
The alarm and pulse LED indicators will flash while the delay time
is in progress (1 sec ON - 1 sec Off) and the countdown will be
shown on the display in seconds. If the pump is in Stop mode, the
LEDs alone will be flashing. While the time delay is in progress, the
function can be disabled by accessing the menu and setting the
time to Off.
Press
to access the modification option and use the
buttons to set the desired value. Press
return to the main menu.
The memorized cc value per strike appears in the main
menu. It can be calibrated in two different ways:
MANUAL – manually enter the cc value per strike using the
keys and confirm by pressing the
AUTOMATIC – the pump makes 100 strikes, which are
started by pressing the
process, enter the quantity sucked up by the pump using
the
keys and confirm by pressing the
The entered figure will be used in flow calculations.
rev. 1.0
Operation
to confirm and
Operation
,
key. At the end of this
and
key
key.
8

Publicité

loading