6. Putting into use
Warning:
High voltages are hazardous for people who have a pacemaker.
-
Ensure that the generator is properly earthed.
-
Touching live parts of the charging bar/electrode will cause an unpleasant electrical
-
shock.
6.1. Switching on and off
- Switching on = [0 / l] switch in [l] position.
- Switching off = [0 / l] switch in [0] position.
When the equipment is switching off, the overload LED lights briefly.
6.2. Setting the output voltage
Attention:
Avoid unnecessarily high output voltages, otherwise spark-over can occur on the
-
charging bars or electrodes. This will impair the reliability and proper functioning of
the charging process.
The maximum output voltage can be internally restricted. For this purpose, contact Simco-
-
Ion or your regional agent.
With the [ ] / [ ] keys) or remote (0-10V), the output voltage can be adjusted. The selection can
be made with a solder connection (external Setpoint Enable) on the SubD connector at the rear
of the unit.
6.2.1. Using the keys:
The output voltage is set using the [ ] / [ ] keys. Briefly pressing the [ ] key increases the
output voltage by 1 increment, briefly pressing the [ ] key decreases the output voltage by 1
increment. 1 step is 1 % of the maximum value (200 V). If the keys are pressed for a longer
time, the output voltage will rise/fall in steps automaticaly.