Procedure without code:
seconds.
If the alarm unit detects an error, it ignores the error. Supervision is activated but the
event is stored in the event log.
The time delay on exit is activated and the alarm unit generates one beep. During the time
delay on exit, the alarm unit generates a continuous audio signal and LED 1 blinks. You
must exit from the partial supervision area before the end of the time delay.
The alarm unit activates partial supervision at the end of the time delay.
● Activating partial supervision from a remote keypad or remote
control unit
Partial supervision can be activated from a remote keypad or directly from a remote control
unit (key 3) using the same procedure.
If the alarm unit detects an error, partial supervision is inhibited.
You cannot force the activation of partial supervision from the keypad or the remote
control unit. Check the error displayed on the alarm unit.

7. SOS Calls

You can make SOS calls from the alarm unit, the keypad or the 4-function remote control
unit.
To make an SOS call from the alarm unit or the keypad, simultaneously
hold the SOS key and the key between the SOS key and Fire key
depressed for two seconds (to prevent false alarm calls). When the call is
connected, an indicator on the alarm unit lights up.
To make an SOS call from the remote control unit, hold the SOS key (key 19) depressed
for more than two seconds.
The alarm unit then calls the call reception centre without activating the siren.

8. Fire Calls

You can make Fire calls from the alarm unit or the keypad.
To make a Fire call from the alarm unit or the keypad, simultaneously
hold the Fire key and the key between the SOS key and Fire key
depressed for two seconds (to prevent false alarm calls).
The alarm unit makes a call to call reception centre.
Hold Partial supervision on (key 3) depressed for 2