Installation Conditions - Graf CARAT XXL Notice De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Covering heights with telescopic dome shaft in green
areas
Max. covering heights 1500 mm with extension and
telescopic dome shaft.
Max. covering heights with cast telescopic dome
shaft (with class B cast cover) in areas with car traf-
fic (load up to 3.5 t).
Max. covering heights with truck telescopic dome
shaft (with Class D cover to be provided by custom-
er) in areas with truck traffic (load up to 40 t).
The tanks can be only partially installed into the
groundwater. If it is to be expected that the ground
water could rise higher, even occasionally, as shown
in the figure opposite, the ground water must be
discharged via a drain line.
mail@graf.info
www.graf.info
2.

Installation conditions

Mini telescopic dome shaft
3 /
Maxi telescopic dome shaft +
Telescopic with cast Iron lid
750-950 mm
max. 1500 mm
>800 <1500 mm
>1000 <1500 mm
>800 <1500 mm
750-1050 mm

Publicité

Table des Matières
loading

Table des Matières