• Use the original packaging if the device is to be transported.
• All modifications of the device are forbidden for safety reasons.
• Only use the device for its intended purpose. All other uses may lead to short circuits, burns, electroshocks,
crash, etc. Using the device in an unauthorised way will void the warranty.
4. Installation
a) Fixture
• Hang the VDPLW1028 into a suitable place at the desired angle.
• Use a water-proof cover if you want to use it outdoor.
• Insert the power cord into a suitable power supply (230VAC / 50Hz).
• Switch off the power of the VDPLW1028 when not in use.
• The LED wash is DMX-controlled by a 3-pin XLR cable (1 = GROUND, 2 = DATA-, 3 = DATA+).
b) Fuse
• Only fit or replace a fuse when the device is unplugged from the mains.
• Replace a blown fuse with a fuse of the same type and rating (see "Technical Specifications"):
1. Remove the fuse holder (1) at the back of the device using an appropriate screwdriver.
2. Remove the old fuse and install a new one.
3. Replace the fuse holder and fasten it with the screwdriver.
c) Mounting the Device
• Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable norms.
• The carrying construction must be able to support 10 times the weight of the device for 1 hour without deforming.
• The installation must always be secured with a secondary attachment e.g. a safety cable.
• Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified technician
check the device once a year and once before you bring it into service.
• Install the device in a location with few passers-by that is inaccessible to unauthorised persons.
• Overhead mounting requires extensive experience: calculating workload limits, determining the installation
material to be used... Have the material and the device itself checked regularly. Do not attempt to install the
device yourself if you lack these qualifications as improper installation may result in injuries.
• Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws.
• Make sure there is no flammable material within a 0.5m radius of the device.
• Have a qualified electrician carry out the electric connection.
• Connect the device to the mains with the power plug. Do not connect it to a dimming pack.
• The installation has to be approved by an expert before the device is taken into service.
5. Use
• Auto: Set the DIP switches as follows (+ means ON, - means OFF):
Function
1
Red
2
Green
3
Blue
4
Strobe
VDPLW1028
№1
№2
№3
+
-
-
-
+
-
-
-
+
Speed
Speed
Speed
1
2
3
№4
№5
№6
-
-
-
-
-
-
-
-
-
Speed
Red:
+
4
off/on
2
№7
№8
№9 №10
-
-
-
-
-
-
-
-
-
Green:
Blue:
-
off/on
off/on
-
-
-
-
VELLEMAN