List of parameters and Factory stored programs
Function
Preflow
Starting Current
Initial slope
Operating Amperage
Final Slope
Finishing Current
Post flow
Percent of Peak Current /
Duty Cycle
(Only when pulse function is
enabled)
Pulses-Per-Second DC
(Only when pulse function is
enabled)
Pulses-Per-Second AC
(Only when pulse function is
enabled)
Background Current
(Only when pulse function is
enabled)
SPOT time
(Only when spot function is
enabled)
Low level background
(Only when Bi-Level function
is enabled)
Function
EN Offset
EP Offset
AC-Balance
AC-Frequency
Note A: When AUTO is selected means 1s/10A;
minimun value is 3s.
Note B: for frequency value higher than 500Hz, PEAK is
locked to 50%.
Note C: In AC polarity the pulse frequency is limited to ¼
English
Factory Configuration Default
.5
100
0.1
50
0
30
AUTO
40
0.1
0.1
25
0
25
AC Wave Balance
Factory Configuration Default
AUTO
AUTO
AUTO
120
Selectable Value Range
0 - 25s (step 0.1s)
10 – 200 % (step 1%)
0 – 5s (step 0.1s)
2 – 300 A (step 1A) (TIG)
5 – 270 A (step 1A) (Stick)
0 - 25s (step 0.1s)
10 – 90 % (step 1%)
0.1 - 60s (step 0.1s)
Note A
5-95 (step 5%)
Note B
0,1 – 10 Hz (step 0.1Hz)
10 – 500Hz (step 1Hz)
500 – 2000Hz (step 10Hz)
0,1 – 10 Hz (step 0.1Hz)
10 – 100Hz (step 1Hz)
Note C
10 -90 % (step 1%)
0 – 10s (step 0.1s)
10 – 100s (step 1s)
10 -90 % (step 1%)
Selectable Value Range
2 – 300A (step 1A)
2 – 300A (step 1A)
35 – 95 % (step 1%)
40 – 400Hz (step 1Hz)
of the AC-frequency: : if AC frequency is 120Hz that
means the max pulse frequency is 30Hz . If the pulse
frequency is higher than 1/10 of the AC frequency, the
PEAK is fixed to 50%.
15
Displayed
Displayed
parameter
name
value
Current
PRE
selected value
(s)
Current
STRT
selected value
(%)
Current
UP
selected value
(s)
Current
selected value
(A)
Current
DOWN
selected value
(s)
Current
END
selected value
(%)
Current
POST
selected value
(s)
PEAK
% of FREQ
Current
FREQ
selected value
(Hz)
Current
FREQ
selected value
(Hz)
Current
BACK
selected value
(%)
Current
SPT
selected value
(s)
Current
A2
selected value
(%)
Displayed
Displayed
parameter
value
name
Current
EN
selected value
(A)
Current
EP
selected value
(A)
Current
%BAL
selected value
(%)
Current
FREQ
selected value
(Hz)