Function and features
The contour sensor uses backlight to compare the contours on an
object with reference contours. Depending on the degree of mat-
ching the test object is classified as being a good object or a bad
object.
Operating distance L
When selecting the operating distance it has to be taken into account
that the relevant contour or the relevant contour areas should cover
approx. 50 ... 70 % of the field of view (see illustration on the next
page). For the operating distance L depending on the application plea-
se see the following table.
Typ O2D200, O2D201
Operating distance L [mm]
Field of view
Typ O2D202, O2D203
Operating distance L [mm]
Field of view
Typ O2D204, O2D205
Operating distance L [mm]
Field of view
The size and the mounting position of the backlight should be selec-
ted so that the object or the relevant object areas are sufficiently illu-
minated.
75
[mm]
14x18
50
[mm] 14.5x19 22x28 29x37.5
50
[mm] 22x28
33x42
100
200
20x26
40x52
75
100
75
100
43.5x56 87x112
400
80x104
200
400
58x75
116x150
200
400
174x224