Timing diagram inputs/outputs
OUT ready
OUT not ready
OK
not OK
The evaluation time t
and the number of contours.
Typical evaluation times:
80...150 ms (without connection to the operating program)
1...2 s (with connection to the operating program)
trigger
enabled
The trigger disable time t
rating program and sensor has been established. It is max. 3 s if the
operating program is connected with the sensor.
10
triggering on
positive edge
t
E
differs depending on the selected image section
E
change of the
configuration file
trigger
disabled
is max. 1 s if no connection between ope-
p
trigger
enabled
trigger
input
t
E
output
READY
output
OUT
trigger
trigger
disabled
enabled
switching
input IN0
switching
input IN1
output
READY
trigger
input