Suction turbine does
not run.
Vacuum turbine is run-
ning but the machine
is not sucking in dust /
dirt.
Suction capacity
decreases.
Dust comes out while
vacuuming.
Semi-automatic filter
dedusting does not
work.
Semi-automatic filter
dedusting does not shut
off.
Semi-automatic filter
dedusting cannot be
switched on.

Accessories and Spare Parts

Only use original accessories and
spare parts, they ensure the safe and
trouble-free operation of the device.
Translation of the original instruction
- Check the receptacle and the fuse of the power
supply.
- Check the power cable, the power plug and
possibly the receptacle of the device.
- Turn on the appliance.
- Float is blocking the suction canal.
- Empty the dirt container.
- Remove choking of suction nozzle, suction tube,
suction hose, or cartridge filter.
- Replacing the full fleece filter bag.
- Press the semi-automatic filter dedusting key
five times with the appliance
switched on.
- Change cartridge filter.
- Check the proper installation of the cartridge
filter.
- Change cartridge filter.
- Suction hose is not connected.
- Inform Customer Service.
- Inform Customer Service.