Dometic CAM 360 AHD Instructions De Montage page 32

Masquer les pouces Voir aussi pour CAM 360 AHD:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 64
Video system settings
➤ Turn on the ignition to activate the system.
➤ Press the
button on the remote control.
➤ Select "CALIBRATION".
➤ Enter the password "654321".
Calibration with 4 calibration mats
CALIBRATION
PATTERN 4
PATTERN
WIDTH
2.5m
LENGTH
10.0m
OFFSET
0.0m
BV HIGH
15
➤ Adjust the value of „PATTERN" to „PATTERN 4".
➤ Select the single camera views one at a time.
➤ Check whether the camera angles are set so that the complete calibration mat
can be seen.
➤ If necessary, change the position of the calibration mat.
➤ Measure the dimensions W, L and O in meter (fig. l, page 10).
➤ Enter the dimension W in m for the "WIDTH".
➤ Enter the dimension L in m for the "LENGTH".
➤ Enter the dimension O in m for the "OFFSET".
➤ Select "CALIBRATION".
32
CAM360AHD
CALIBRATION
SINGLE CAMERA
SAVE
EN

Publicité

Table des Matières
loading

Table des Matières