Battery charger SMC-HF 3200, 8000
Instructions
Please read through these instructions carefully before using the
battery charger. Store the instructions in a safe place so that anyone
using the battery charger always has access to them.
General
SMC-HF 3200, 8000 is a regulated battery charger. SMC-HF is available in different
designs for charging either flooded or valve-regulated lead/acid batteries.
They can also be equipped with a charging curve for NiCd batteries or other similar
batteries.
The battery charger is supplied with a pre-set charging curve adapted for the
battery type specified on order.
The built-in microprocessor controls the current and voltage during the charging process.
The charging process is shown on an LED display on the battery charger's panel. The
charging time and temperature of the battery charger are monitored, and charging is
limited, for instance, when there is a fault in the cells or cooling is inadequate. Throughout
the charging process, the battery charger collects data and performs calculations in order
to ensure the battery is fully charged based on the level of discharge, temperature, age,
etc. The battery charger is cooled by a temperature-regulated fan.
Safety
The battery charger is only intended for use in clean, dry environments.
Follow the battery supplier's instructions for handling batteries.
Only use accessories explicitly recommended by the supplier.
The battery charger must only be used with the battery types for which it is designed.
The battery charger is supplied with a pre-set charging curve adapted for the
battery type specified on order.
When changing battery type, you must contact the supplier to check if the battery
charger needs reprogramming. If the battery charger is not set correctly, the battery
may be damaged.
Disconnect the battery and mains power supply before undertaking maintenance,
troubleshooting or cleaning the battery charger.
The battery charger must only be connected to an earthed wall socket.
Do not use the battery charger if it is damaged. Do not touch damaged parts.
Disconnect the mains power supply immediately and contact service personnel.