Assembly and Operating Instructions
Nominal voltage
Type of battery
Protection class
Permissible surrounding temperature
Radio frequency
Problem
Drive is not functioning. 1. Battery is discharged.
The required drive is
not functioning.
18
Technical data
What to do if ...?
Cause
2. Battery is inserted
incorrectly.
3. Receiver is out of the
radio operating range.
4. The EC315 is not
programmed in the
receiver.
Incorrect channel
selected.
3 V DC
CR 2430
IP 20
-10 to +55 °C
868.3 MHz
Remedy
1. Replace battery.
2. Insert battery correctly.
3. Reduce distance to
receiver.
4. Programme the EC315.
Correct channel selected