Control panel
000
1
000
Lock Temp.Volume Confirm
2
3
4
5
1.
Display
2.
LOCK button
3.
TEMP modification button
4.
VOLUME modification button
5.
CONFIRM button
BCWD-5L
H
A
G
B
C
F
D
E
A.
Display
B.
Control panel
C.
Water nozzle
D.
Drainer
E.
Stand
F.
Power cord
G.
Water tank
H.
Water tank cover
Control panel
1
95°C
500ml
1
2
8
85°C
3
4
350ml
50°C
240ml
PURE TOS RAW TDS
7
TEMP
VOLUME
6
5
4
1.
Condition of filter cartridges (1. Mesh filter; 2.PP +
CTO; 3. RO; 4. ACF)
2.
Capacity indicators
3.
Raw water
EN
4.
VOLUME modification button
5.
Confirmation button and water level indicator
6.
TEMP modification button
7.
Purified water
8.
Temperature indicators
Filter description
PP+CTO
Cotton filter with
3-6 months
activated charcoal
RO
Membrane reverse
12-24 months
osmosis filter
ACF
Carbon fibre filter
8-12 months
Note: The life of filters depends on the quality of the water
used.
3.2. PREPARING FOR USE
APPLIANCE LOCATION
The temperature of environment must not be higher than
40°C and the relative humidity should be less than 85%.
Ensure good ventilation in the room in which the device
is being used. There should be at least 10 cm distance
between each side of the device and the wall or other
objects. The device should always be used when positioned
on an even, stable, clean, fireproof and dry surface, and
be out of the reach of children and persons with limited
mental and sensory functions. Position the device such that
you always have access to the power plug. The power cord
connected to the appliance must be properly grounded
and correspond to the technical details on the product
label.
Before first use, remove the water tank and clean it using
warm running water and a mild detergent. It is also
recommended to flush the entire device water system
several times before using the water for food purposes.
3.3. DEVICE USE
BCWD-4L
1.
Place the device on a flat, dry, clean and fireproof
surface.
2.
Ensure that the device is disconnected from the
power supply.
3.
Open the water tank cover.
4.
Top up the water in the tank.
Note: The water level in the tank should not exceed
the MAX value.
5.
Connect the device to a power source.
6.
Place the water collecting container under the nozzle
on the drip tray.
7.
Press and hold the LOCK button to unlock the
2
control panel.
8.
Press the TEMP button to select the water
temperature (45> 55> 65> 75> 85> 100 [° C]).
9.
Press the VOLUME button to select the water volume
3
(0> 100> 200> 300 [ml]).
10.
Press the CONFIRM button. The device will start
working.
11.
The device will produce a sound signal when it stops
working.
Note: the message E7 on the display, accompanied
by an audible signal, means that you need to top up
the water in the tank
10
BCWD-5L
Note: The device will start flushing during the first
start-up. Simultaneously, the confirm button will
alternate on and off. When the signal stabilizes, you
can start working with the device.
1.
Place the device on a flat, dry, clean and fireproof
surface.
2.
Ensure that the device is disconnected from the
power supply.
3.
Open the water tank cover.
4.
Pull out the water tank and top it up with water.
5.
Put the water tank back in its original position.
6.
Close the water tank cover. Make sure that the tank
is seated correctly and the cover is closed.
7.
Connect the device to a power source.
8.
Place the water collecting container under the nozzle
on the drip tray.
9.
Press the TEMP button to select the water
temperature (50>85>95 [°C]).
10.
Press the VOLUME button to select the water volume
(240>350>500 [ml]).
11.
Press the confirm button. The device will start
working.
12.
The device will produce a sound signal when it stops
working.
13.
Resetting an expired filter: When the display shows
that the filter has expired, press the „Temp" and
„Volume" button for 5 seconds to directly reset the
expired filter element. Filter elements whose life has
not expired will not be reset. When the filter reset
is complete, the buzzer will sound an alarm for 2
seconds.
3.4. CLEANING AND MAINTENANCE
3.4.1 BCWD-4L
A.
Filter replacement
B
H
I
1.
Open the water tank cover.
2.
Remove the container with filter from inside the
device.
3.
Remove the used filter and install a new one.
4.
Place the container with filter in its original position.
B.
Removing residual water from the device
M
EN
1.
Loosen the drainage plug on the bottom of the
device.
2.
Remove the remaining water.
3.
Tighten the drain plug to its original position.
C.
Removing residual water from the drip tray
F
1.
Holding the device with one hand, gently lift and
remove the drip tray.
2.
Clean the drip tray with running water and a soft
cloth.
3.
Install the drip tray in its original position.
3.4.2 BCWD-5L
A.
Maintenance of the mesh filter
1.
Open the water tank cover
2.
Remove the water tank.
3.
Remove the mesh filter from inside the water tank.
4.
Clean the filter under running water with a brush.
5.
Install the filter in its original position.
6.
Install the water tank and close the tank cover.
B.
Replacement of the filters
ACF
PP+CTO
RO
11