SMD REWORK STATION
1.
Device must be placed on stable work table, HOT AIR gun must be placed into the holder.
2.
Fix the appropriate nozzle and connect the device to the power source.
3.
Turn on the device with the main switch placed at the back of the device, turn on the HOT AIR gun with switch (3),
gun will start to heat.
4.
Using buttons (1) set the desired temperature, the display (2) will show this temperature for a moment and then it
will show the actual temperature of the gun. After temperature stabilization, desired air flow volume can be adjusted
by knob (8).
ture value will be lower than 100 ⁰C, the display (2) will show "---" and the device will be in "stand by" mode.
5.
After work, gun should be placed into the holder. Heating will stop and gun will start to cool down. If the tempera-
6.
If the device is not using for a long time, it should be completely disconnected from the power source.
7.
NOTE: It is forbidden to cover the air intake holes on the handle of a SMD rework gun during work. This may cause
serious damages of the fan and the heater!
SOLDERING IRON OPERATION
1.
Device must be placed on stable work table, soldering iron must be placed into the holder.
2.
Fix the appropriate soldering tip and connect the device to the power source.
3.
Turn on the device with the main switch placed at the back of the device, turn on the soldering iron with switch (4),
it will start to heat.
4.
Using buttons (24) set the desired temperature, the display (5) will show this temperature for a moment and then it
will show the actual temperature of the soldering iron.
5.
After work, soldering iron should be placed into the holder and turned off by switch (4).
Switch (6) is designed for changing the temperature units between Celsius and Fahrenheit (⁰C – Celsius, ⁰F – Fahrenheit)
CHANGING THE TEMPERATURE DISPLAY UNITS
DC POWER SUPPLY OPERATION
1.
Device must be placed on stable work table; connect the device to the power source.
2.
Connect the load to the appropriate terminals (+) and (-).
3.
Set the output current value using knobs (14) and (19), then set the desired output voltage value using knobs (16)
and (18).
4.
DC voltage testing:
a. Set the switch (13) on the "TEST VOLTAGE" position.
b. Connect the wires to the (11) and (12) terminals.
c. Connect the load to the wires.
d. ATTENTION! Range of work in this mode is 0 to 50V DC!
If the display is showing the „---„ it means that the output temperature is lower than 100 ⁰C, SMD Rework Station
GENERAL REMARKS
1.
is in stand by mode, HOT AIR gun is placed in the holder.
2.
If the display is showing "S-E" it means that soldering iron is disconnected, and HOT AIR gun is having problem with
the heat sensor.
3.
If the display is showing "F-1" it means that electric circuit of the fan is having problem.
4.
If the display is showing "F-2" it means that the fan is blocked.
5.
When the device is being turned on, both soldering iron and HOT AIR gun should be placed in their holders.
6.
The outlet of the HOT AIR gun should be clean and free from any obstacles.
7.
When using small nozzles, it should be remembered that the air flow should be suitable to the diameter of the fixed
nozzle. In order to avoid any HOT AIR gun damages, too high air flow along with the high temperature mustn't be
used for a long period of time.
8.
Depending on user's needs, different air flow settings may cause slight variations in temperatures value. The mini-
mum distance between the outlet of the HOT AIR gun and the subject is 2 mm.
9.
Good ventilation of the room in which the appliance is used must be provided. In addition, the device should be
placed in a location with good air circulation to dissipate heat.
EN