8.8 Enabling menu access:
26. Press
to access the menu.
27. "Code, 0000" is displayed. The first digit is highlighted.
28. Enter the code by changing the highlighted code digits
with
. Confirm the entry with
highlighted. Change the other highlighted digits in the
same way, by pressing
29. After the last confirmation with
option in the menu is displayed. Access to the menu is
re-enabled. Pressing
menu options to configure other settings. Pressing
shows the start display.
8.9. Reset
The "Reset" and "Factory setting" functions are located under
the "Reset" menu option. The "Reset" function activates and
deactivates and/or restarts the torque wrench with built-in angle
gauge. When "Reset" is selected, the system is brought to a
defined starting condition. This may be necessary if the wrench
no longer functions properly and does not respond to the normal
inputs. The "Factory settings" function returns the torque wrench
with built-in angle gauge to its status upon dispatch from the
factory and activates, reactivates and/or restarts it, just as the
"Reset" function does.
NOTE! Warning, all self-programmed settings, param-
eters sets and workflows will be deleted
8.10. Bluetooth
(Bluetooth Low Energy
(BLE) module)
In the Bluetooth menu option, the torque wrench with built-in
angle gauge connects to mobile end devices that have the
HAZET SmartTAC app installed.
Select the Bluetooth menu option in the menu with the
After pressing the
button, select "On" with the
confirm with the
button.
The Bluetooth menu option appears in the display again.
Change to the start display of the wrench by pressing the
button. After HAZET Smart app starts and the Bluetooth con-
nection activates, the screwing data incl. "Live" signal on the
app's display can be shown. Check the set values carefully on
the start display and confirm them by pressing the
before you operate the torque wrench with built-in angle gauge.
NOTE! The subsequent procedures for applying the
app functions are part of the operating instructions for
the SmartTAC app.
WARNING! The display of the screwing data incl. sig-
nal on the SmartTAC app supports the screwing pro-
gress monitoring of the torque wrench with built-in
angle gauge. Always make sure that the Bluetooth connection is
free of faults and that all screwing data are transferred. The
display and signal of the torque wrench with built-in angle gauge
are always essential. The SmartTAC app allows the settings of
torque wrench with built-in angle gauge to be changed or con-
figured. During the programming using the SmartTAC app,
"Bluetooth Configuration" is shown in the display of the torque
wrench with built-in angle gauge. After the changing of the set-
Design and function
. The next digit is
and confirming with
.
, the "Mode" menu
enables you to select other
button.
button and
button
tings via the SmartTAC app is completed, the start display
appears on the torque wrench with built-in angle gauge.
WARNING! The configuration of the setting values via
the SmartTAC app supports the operation of the torque
wrench with built-in angle gauge. Always make sure that the
Bluetooth connection is free of faults and that all the necessary
settings are transferred. The display in the start display of the
torque wrench with built-in angle gauge is always essential.
Check the set values carefully on the start display and confirm
them by pressing the
button before you operate the torque
wrench with built-in angle gauge.
NOTE! Reduce the rechargeable battery's power con-
sumption by deactivating the live data transfer from and
to the SmartTAC app again once the data transfer is
completed.
8.11. Application / operation
torque wrench with built-in angle gauge
The torque wrench with built-in angle gauge must only be oper-
ated with the handle at right angles to the screw joint. The hand
force deployed must be applied uniformly onto the centre of the
handle (ring marking).
In order to avoid measurement errors when measuring the rotation
angle, do not allow the screwed workpiece or its support to turn,
move or sway during operation.
You can also activate the dimmed display to reduce the power
consumption.
After approx. 30 seconds the display is dimmed slightly.
8.12 PC connection
The torque wrench with built-in angle gauge is ready to be con-
nected to the optionally available Smart Tool software. The sub-
sequent procedures for establishing a connection, reading saved
data and for programming the wrench with the software are part
of the operating instructions for the SmartTAC Tool software.
9. Adjustment / calibration:
Electronic torque wrenches with built-in angle gauge should be
checked and calibrated on a regular basis. After a long period of
use, re-certification or re-calibration by the factory is advisable.
Electronic torque wrenches with built-in angle gauge are measur-
ing tools. Appropriate measurement equipment must be used to
test (and where applicable, adjust) measuring tools at the time
intervals laid down by Quality Management.
The time gap between test dates is dependent on the frequency
of use. We recommend testing after approx. 5000 screw opera-
tions (but the period in-between tests should be no longer than
6 months).
NOTE! The "Version" menu option provides information
on the software version, the serial number, the date of
the last calibration and the remaining number of
releases until the next calibration of the wrench.
1. To access the information in the "Version" menu option,
you must switch to the menu with
"Version" menu option with
2. The software version information is displayed after press-
ing
in the "Version" menu option.
of the