ENGLISH
–
QUICK TIPS FOR REMEDYING
FAULTS
WCFIX will not start up and water remains in the toilet bowl
• Check the mains voltage, fuse is defective
• mains cable is damaged. Notice! The special cable may be
replaced only by our customer service or a qualified electri-
cian.
• Impeller is blocked, see servicing instructions.
Water drains only very slowly from the toilet bowl
• Check the amount of flushing water available in the toilet
cistern and set it to nine litres or to the maximum quantity
if necessary. If more water than usual remains in the toilet
bowl, flush again and repeat, if necessary, provided that the
water continues to be pumped out. If this does not help, then
please call customer service.
• Discharge head is too large.
WCFIX switches on repeatedly after normal pumping cycle
• Cistern valve is leaking and water flows constantly through
the toilet bowl and into the unit.
• After the pump stops, water runs back into the WCFIX be-
cause the non-return valve is leaking or defective.
• Obstruction in the tank upstream of the pump, resulting in
water only being pumped away at short intervals.
Noisy operation
• Foreign matter in the unit. Follow servicing instructions.
• Note. Due to the fact that the switching points are automati-
cally calibrated after operation, a louder noise is heard after
every 15th start-up.
Alarm signal sounds
• Running time too long (> 43 seconds), because the pressure
pipe or pump suction opening is blocked.
• Water level in the WCFIX is too high, because the pump is
obstructed or blocked.
Periodic blocking
• No homogenisation of the waste matter = extend the shut-
off delay time until sipping mode can be heard.
16
JUNG PUMPEN GmbH - Industriestr. 4-6 33803 Steinhagen, Germany
451.12.1701
EN 12050-3:2001
Lifting plant for limited applications
WCFIX 260 (JP09268/1)
WCFIX PLUS (JP45367)
WCFIX PLUS UK (JP48517)
Automatic lifting of wastewater above the backflow level, for limited appli-
REACTION TO FIRE
WATERTIGHTNESS, AIRTIGHTNESS
- Water tightness
- Odour tightness
EFFECTIVENESS (LIFTING EFFECTIVENESS)
- Pumping of solids
- Pipe connections
- Minimum dimensions of ventilating pipes system
- Minimum flow velocity
- Minimum free passage of the plant
MECHANICAL RESISTANCE
NOISE LEVEL
DURABILITY
- of structural stability
- of lifting effectiveness
- of mechanical resistance
DANGEROUS SUBSTANCES
0197
13
cations.
NPD
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
70 dB(A)
Pass
Pass
Pass
NPD