2.2 Electrical connection

WARNING!
Risk of fire and electric
shock.
• All electrical connections should be
made by a qualified electrician.
• The appliance must be earthed.
• Make sure that the parameters on the
rating plate are compatible with the
electrical ratings of the mains power
supply.
• Always use a correctly installed
shockproof socket.
• Do not use multi-plug adapters and
extension cables.
• Make sure not to cause damage to
the mains plug and to the mains
cable. Should the mains cable need to
be replaced, this must be carried out
by our Authorised Service Centre.
• Do not let mains cables touch or
come near the appliance door or the
niche below the appliance, especially
when it operates or the door is hot.
• The shock protection of live and
insulated parts must be fastened in
such a way that it cannot be removed
without tools.
• Connect the mains plug to the mains
socket only at the end of the
installation. Make sure that there is
access to the mains plug after the
installation.
• If the mains socket is loose, do not
595 mm
• Do not pull the mains cable to
559 mm
• Use only correct isolation devices: line
569 mm
• The electrical installation must have
548 mm
1022 mm
560x20 mm
• This appliance is supplied without a
4x25 mm
For the section of the cable refer to the
total power on the rating plate. You can
also refer to the table:
The earth cord (green / yellow cable)
must be 2 cm longer than phase and
neutral cables (blue and brown cables).
2.3 Use
• This appliance is for household
• Do not change the specification of this
• Make sure that the ventilation
• Do not let the appliance stay
• Deactivate the appliance after each
connect the mains plug.
disconnect the appliance. Always pull
the mains plug.
protecting cut-outs, fuses (screw type
fuses removed from the holder), earth
leakage trips and contactors.
an isolation device which lets you
disconnect the appliance from the
mains at all poles. The isolation
device must have a contact opening
width of minimum 3 mm.
main plug and a main cable.
Cable types applicable for installa‐
tion or replacement for Europe:
H07 RN-F, H05 RN-F, H05 RRF, H05
VV-F, H05 V2V2-F (T90), H05 BB-F
Total power (W)
maximum 1380
maximum 2300
maximum 3680
WARNING!
Risk of injury, burns and
electric shock or explosion.
(indoors) use only.
appliance.
openings are not blocked.
unattended during operation.
use.
ENGLISH
5
Section of the ca‐
ble (mm²)
3 x 0.75
3 x 1
3 x 1.5