DE CÔTÉ DU FOYER
AU MUR LATÉRAL
DE LA PORTE DU
FOYER (OUVERTURE)
AU MUR LATÉRAL
(203mm)
BANDES D'ÉTANCHÉITÉ
EN MÉTAL
Figure 3.1, Dégagements d'installation exigés
#Z-42 & #Z-42-CD R.18 Décembre 2020
L'ESPACE SITUÉ DIRECTEMENT AU-DESSUS DU
FOYER DOIT ÊTRE LAISSÉ VIDE ET NE DOIT ÊTRE
REMPLI AVEC AUCUN MATÉRIAU (SAUF LE CADRE DE BOIS).
N'INSTALLEZ AUCUN PLACARD OU TABLETTE DANS CETTE ZONE.
PROJECTION DU MANTEAU
8"
(203mm)
3"
(76mm)
8"
PROTECTION DE PLANCHER
EN MATÉRIAU NON-COMBUSTIBLE
AYANT UNE VALEUR R MINMALE DE 0,8
48"
1219
(
mm)
LARGEUR MINIMALE DE
EXTENSION D'ÂRTE
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
DU DESSUS DU
FOYER AU MANTEAU
12"
HAUTEUR
(305mm)
MINIMALE DU CADRE
(1,83m)
16"
(406mm)
PROFONDEUR MINIMALE
DE EXTENSION D'ÂRTE
Encadrement utilisant des colombages 2 po x 4 po (nominal).
72"
PLANTIFICATION D'INSTALLATION 11