8
MOUNTING THE BOWL AND
CUTTING OUT THE PANEL
IMPORTANT:
Make sure to install the toilet
seat before mounting the bowl.
1 -
When the frame is placed against a wall;
cut strips of cement board (or gypsum
board) to cover the sides and front of the
frame.
2 -
When the frame is inside a wall, board the
entire opening.
3
- Note. Make a 1-inch (25 mm) hole in the
board (corresponding with the threaded
rods). This will allow you to adjust the
depth of the rod later.
IMPORTANT:
Make sure to have an access
panel in order to minimize any extra work in
case of service.
4
- Place the template
against the wall,
E
positioning the holes for the WC supports
rods accordingly.
5 -
Trace the inner shape of the template
onto the front.
6
- Remove the template
E
opening as traced, being careful not to
cut any pipe or wire.
7
- Note. If you are tilling the wall, the tiles
will have to be cut out in the shape of the
inner opening.
8 -
Finish the support wall and place the
template onto the screws.
9
CONNECTIONS
WARNING:
Before making the various
connections, check the following:
1
- Ensure that the treaded rods are correctly
spaced and the dimensions in drawing
adhered to, otherwise the screw
7a
covers will not fit.
2
- Put the template
in place onto the
E
threaded rods.
CONNECTION OF SINk
9a
1 -
Remove the cap of the waste inlet loca-
ted underneath the water inlet.
2 -
Connect the rubber waste connection
to the spigot with the correct clip
I
and crimp it with either a set of pliers or
crimpers.
3 -
Connect the other end of the connector
to the 1 1/4-inch (32 mm) end
I
of sink waste pipe and secure it with
clip
.
K
DISCHARGE CONNECTION
9b
1 -
Slide tube
onto the discharge
F
connector.
2 -
Fix the discharge elbow/check valve
assembly
, with clip
G
H
discharge pipe.
3 -
WARNING:
The non-return valve must
be installed vertically with the arrow
pointing upwards.
4 -
Stretch the connector and fix the end to
the non-return valve-using clip
9c CONNECTION OF THE WATER SUPPLY
Connect the water supply hose to the
compression fitting.
9d ELECTRICAL CONNECTION
Plug the cord into the receptacle.
10
MOUNTING THE BOWL
Once the connections have been made,
1 -
Ensure that the clear tube
the treaded rods.
2 -
Push the bowl onto the treaded rods;
secure the nuts (with washers) without
over-tightening them.
11
START-UP AND
PROGRAMMING
START-UP
11a
1 -
Plug in the power socket. Wait 20
seconds: appliance initializing. Open the
water tap to rinse well. Start the normal
flush by pressing the dark grey button.
Put a few sheets of toilet paper down in
the bowl and flush again.
Note:
This unit does not need to be vented.
2 -
Turn on the sink tap. The unit should
sink activate automatically.
and cut out the
3 -
Demount the bowl and check the water
tightness of all connections.
WARNING:
4 -
the unit to activate automatically.
PROGRAMMING
11b
The length of your SANISTAR
according to which cycle you choose.
Eco flush (by default, light grey button):
19 seconds and 1 gallon (3.8L): rinsing of the
bowl for 10 seconds, the pump works for 7
seconds (for 7 seconds, the bowl continues
to fill), then the bowl fills again for 2 seconds.
You can lengthen the first rinse of the eco
flush to 16 seconds if the default flush is not
enough.
Normal flush (dark grey button):
25 seconds and 1.32 gallons (5L): The bowl is
rinsed for 16 seconds, the pump works for 7
seconds (for 7 seconds, the bowl continues to
fill) then the bowl fills again for 2 seconds.
To re-program:
J
Note:
Only the ECO option can be reprogram-
med.
• Hold the ECO button (light grey button)
down for 5 seconds.
• The motor works for 2 seconds, this means
you have entered programming mode.
• Each time you press the dark grey button
you increase the length of the ECO flush
by 1 second: each time you press it will be
validated by the motor running for a short
period.
• Each time you press the grey button you
decrease the length of the flush by 1 second:
to the
each time you press it will be validated by
the motor running for a short period.
To exit programming mode:
• Wait for 5 seconds without pressing any
buttons.
The motor runs for 2 seconds, this means
.
H
that you have left programming mode.
Comment 1: the minimum length of the first
rinsing flush for the normal flush is 19 seconds
(default programming)
and the maximum length is 25 seconds.
Comment 2: the normal flush cannot be
modified.
is still on
D
Leaking faucets will cause
's flush varies
®
12
COMPLETING THE
INSTALLATION
1 -
Remount the bowl onto the treaded
rods.
2 -
Sequence of washers, place first the
white PVC washer
L
then the steel
washer onto the treaded rods and
tighten the nuts
. Then snap the nut
B
covers
in place.
M
3 -
Cut away any protruding lip of the
template around the bowl contour.
4 -
Seal the bowl/wall joint with silicon.
13
USAGE
1 -
The SANISTAR
pump/macerator does
®
not require any special maintenance.
WARNING:
The SANISTAR
2 -
only be used for the evacuation of
normal human waste, toilet paper and
household toilet cleaners.
Damage may occur to the motor if
the following are disposed of via the
toilet: cotton wool, tampons, sanitary
napkins, wet wipes, kitchen towels,
condoms, dental floss as well as other
fabric or hard objects. Solvents, acids
and other chemicals can also cause
damage to the unit, and will invalidate
the warranty.
WARNING:
3 -
In case of prolonged power
failure, or going on vacation, please
close the stop valve of the the sink and
water supply.
14
CARE OF YOUR
SANISTAR
®
• Normal household bleaches/WC cleaners can
be used with a SANISTAR
®
• To avoid the build up of lime scale in the
unit, use the following procedure:
• disconnect the power supply to the unit,
• pour 1 gallon (3 to 4 liters) of water
mixed with a strong solution of descaler
into the bowl,
• leave it to stand for 1 or 2 hours, then
re-connect the electric supply,
• flush several times to clear.
The frequency of this operation will depend on the
hardness of the water in your locality. We would
recommend this be done about twice a year.
15
AFTER SALES SERVICE
In the unlikely event of a failure or
malfunction, please call our after sales
service department.
WARNING:
Always disconnect the electric
supply before attempting any work on the
SANISTAR
.
®
16
WARRANTY
The SANISTAR
is guaranteed for 2-year,
®
subject to correct installation and usage.
should
®
.