9.0 Electrical Connection

WArNiNg: This appliance must be earthed. The electrical installation must comply with local or national
wiring regulations.
l The electrical installation of this appliance should be carried
out by a qualified electrician in accordance with current
regulations.
l This unit is supplied with factory fitted test leads. Remove these
and discard.
l A fused electrical spur with a maximum 3A fuse and a switch
having 3mm separation on all poles must be provided in an
easily accessible position adjacent to the unit.
l Electrical cable entry to the unit should be made through the
underside of the unit, into the control box on the right hand
side using the cable gland provided. The supply cord must be
0.75mm² only.
1. Remove x 2 screws to access control panel
10
l Connect the live and neutral wires to the power board
terminal connections, and the earth wire to the chassis earth
terminal.
For building Management System
l Connect wires from BMS and valves as necessary, using the
same cable routing into the control box, and with the second
cable gland supplied.