Duct Cover Installation
6. Slide the inner duct cover up and secure with
for (4x8mm) screws (provided) to the upper
telescopic stack. Refer to Figure 5.
Hood Installation
7. Slide outer duct cover up and place 4
temporary screws to hold the duct cover.
Refer to Figure 6.
8. Install the hood using eight (3/16 x 3/8mm)
screws
(provided)
telescopic stack. Make sure to tighten screws
securely. Refer to Figure 7.
Wiring to Power Supply
SAFETY WARNING
RISK OF ELECTRICAL SHOCK. THIS RANGE
HOOD MUST BE PROPERLY GROUNDED.
MAKE SURE THIS IS DONE BY SPECIALIZED
ELECTRICIAN IN ACCORDANCE WITH ALL
APPLICABLE
ELECTRICAL
CONNECTING WIRES, SWITCH POWER OFF
AT SERVICE PANEL AND LOCK SERVICE
PANEL TO PREVENT POWER FROM BEING
SWITCHED ON ACCIDENTALLY.
9. Connect three wires (black, white and green)
to house wires and cap with wire connectors.
Connect according to color: black to black,
white to white, and green to green.
10. Test the operation of the hood before moving
on to next step. Make sure power is supplied
to the hood.
Ductwork Installation
11. Use 6" round pipe to connect the plastic
exhaust on the hood to the ductwork above.
12. Use duct tape to make all joints secure and
are tight.
to
secure
hood
NATIONAL
AND
CODES.
BEFORE
Figure 5
to
Figure 6
LOCAL
Figure 7
8