THEIS VISION 2N AUTOSLOPE ALIGN Instructions De Service page 55

Masquer les pouces Voir aussi pour VISION 2N AUTOSLOPE ALIGN:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Press A key briefly:
Start ALIGN in X axis.
Search complete:
X or -X alternating and slope
value _._ _ flashing in alterna-
tion.
End ALIGN:
Press A key briefly:
ALIGN deactivated.
Detector is now in
standard operation and
can be re-moved.
The inclination of both axes will be monitored from that moment
and readjusted if necessary to compensate changes of the laser
position. See also Section 4 because of warnings.
Table 3: ALIGN - Function horizontal Y – and X-axis
Important: If the laser is brought out of position accidentally,
the entire measurement will have to be repeated.
Laser searches
for detector.
Detector found.
Detector - Track-
ing stops.
Grade value X
stored.
Laser in standard
grade function.
55
0.00%
Y
_._ _%
A
X
_._ _%
Y
_._ _%
A
X
_._ _%
Y
_._ _%
A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vision 2n align

Table des Matières