End ALIGN:
Press A key briefly:
ALIGN deactivated.
Detector is now in
standard operation and
can be re-moved.
Table 2: ALIGN - Function horizontal Y-axis
12.1.2.2 Slope Y- and X - axis (Figure 1)
TE 90 ALIGN
Turn on the detector.
Device symbol must al-
ways be displayed.
Set detector at short distance before laser to reference height.
Then move detector to target point M2. M2 must be exactly on the
Y axis (telescopic sight recommended).
Y axis
Press A key briefly.
Start ALIGN in Y axis.
Search complete:
Y or -Y alternating and slope
value _._ _ flashing in alterna-
tion.
X axis
Press Display accuracy
key/X.
The inclination of the Y-axis will be monitored from that moment
and readjusted if necessary.
Move detector to target point M3 for X – slope.
Detector - Track-
ing stops.
Grade value Y
stored.
Laser in standard
grade function.
VISION 2N ALIGN
Turn on the laser.
Laser approach-
es end switch
and levels.
Leveling begins.
Laser searches
for detector.
Detector found.
Grade value Y is
stored.
H
54
Y
_._ _%
0.00%
A
Y
_._ _%
A
0.00%
Y
_._ _%
A