Cleaning Agents - Truvox Orbis Battery Scrubber II Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CLEANING AGENTS

1.
When using cleaning and care agents, the manufacturer's
danger warnings must be followed and protective goggles
and clothing must be worn.
2.
Only use low-foaming, non-combustible cleaning agents
which DO NOT contain generally health-hazardous
substances.
3.
Please ensure that after each use any chemical residue is
rinsed out with clean water.
TRANSPORTING THE MACHINE
Take extreme care when moving the machine up or down
steps or stairs.
Incorrect lifting techniques may result in personal injury.
We advise that the manual handling regulations are
followed. Carefully wrap the charger power cord and store
in dry indoor location. Incorrect lifting techniques may
result in personal injury. We advise that the manual
handling regulations are followed. DO NOT expose the
machine to rain or moisture.
When
transporting
components, tanks and removable parts are securely
fastened, and that the charger power cord and plug are not
trailing.
Ensure the machine is empty prior to lifting or transporting.
CAUTION - Bumping over thresholds, kerbs and similar
obstacles can damage the machine. Small obstacles can be
overcome by pulling the machine backwards.
Do not attempt to lift the machine without assistance.
When transporting the machine the handle should be
locked in the upright position.
STORAGE
Always switch off the machine after use.
Store the machine in a dry indoor area only.
Never store the machine with a brush fitted as this causes
distortion, and results in instability during operation.
Always switch off, empty, wipe down and dry the machine
after use.
Both the solution and recovery tanks should be emptied
and flushed out with clean water to ensure the seals and
pumps are free from any cleaning detergents.
IMPORTANT – To dispose of unused cleaning solution,
comply with the standards in force in the country in which
the machine is being used.
IMPORTANT – To dispose of the recovery water tank,
comply with the standards in force in the country in which
the machine is being used.
MAINTENANCE
WARNING - Before undertaking maintenance
operations or adjustments switch off machine
and unplug from the electricity supply.
IMPORTANT – All other servicing and repairs should
only be performed by a Truvox engineer or Authorised
Service Agent.
IMPORTANT – Should the machine fail to operate please
refer to the fault diagnosis section in the back of this instruction
manual. If the problem / remedy is not listed please contact
Truvox Customer Service Department for rapid attention.
3
the
machine
ensure
that
The machine requires minimum maintenance apart from the
following checks by the operator prior to use:
Body of the machine - Clean with a damp cloth.
Charger power cord - Regularly inspect sheath, plug and
cord anchorage for damage or loose connection. Only
replace the charger power cord with the type specified in
these instructions.
Solution tank - Check water flow, if restricted inspect
hoses and tubes for blockage or kinks.
Solution tank – Check filter is clean and undamaged. A
damaged or missing filter must be replaced or damage to
pump head and spray jet could occur.
Spray jet – Check jet for blockage and full spray pattern.
Blow through jet to clean. Do not use a pin, as this could
damage the jet.
Drive boards, pads and brushes - Inspect for wear and
replace worn brushes. Clean under running water.
Solution feed filter (Pump) - The filter prevents clogging of
the spray nozzle and should be periodically cleaned.
all
AFTER SALES SERVICE
Truvox machines are high quality machines that have been
tested for safety by authorised technicians. It is always apparent
that after longer working periods, electrical and mechanical
components will show signs of wear and tear or ageing. To
maintain operational safety and reliability the following service
interval has been defined: Every year or after 250 hours. Under
extreme
or
maintenance, shorter maintenance intervals are necessary. Use
only original Truvox spare parts. Use of other spare parts will
invalidate all warranty and liability claims. Should you require
after sales service please contact the supplier from whom you
purchased the machine, who will arrange service. Repairs and
servicing of Truvox products should only be performed by
trained staff. Improper repairs can cause considerable danger to
the user.
GUARANTEE
Your product is guaranteed for one year from the date of
original purchase, or hire purchase, against defects in materials
or workmanship during manufacture. Within the guarantee
period we undertake at our discretion, to repair or replace free
of charge to the purchaser, any part found to be defective,
subject to the following conditions:
CONDITIONS
1.
Claims made under the terms of the guarantee must be
supported by the original invoice/bill of sale issued at the
time of sale, or the machine Serial No.
2.
For claims under this guarantee contact the supplier from
whom you purchased the product who will arrange the
appropriate action. Do not initially return the product as
this could result in transit damage.
3.
Neither Truvox nor its distributor shall be liable for any
incidental or consequential loss.
4.
This guarantee is governed by the laws of England.
5.
This guarantee does not cover any of the following:
Periodic maintenance, and repair or replacement of
parts due to normal wear and tear.
Damage caused by accident, misuse or neglect, or the
fitting of other than genuine Truvox parts.
specialised
conditions
and/or
insufficient
12-18

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Obs38130/g

Table des Matières