To prevent water and odor leakage, please
ensure that the wax seal is fitted properly
between the Socket and the flange. Do not
CAUTION
overtighten the nuts, as damage to the plastic
parts may result.
5.
Place the toilet bowl over the Socket (see Ill. 3). Install
the side screws to the mounting blocks. Cover the
screw head with the provided screw-cap (see Ill. 4).
IMPORTANT: If the side screw does not
engage the mounting blocks, then either the
toilet bowl is not fully inserted in the socket or
the mounting block is not installed properly.
If the toilet is not installed properly, it may
CAUTION
slide out of socket and leak may result. Please
ensure that both sides are properly fitted and
secure. Be sure not to over-tighten the screws,
as it may results in product damage.
NO TE: Three Points of Contact:
The toilet bowl has three points of contact, which
will actually contact the bottom of the toilet
tank when properly installed. The location of
these points can be seen on the bowl at the tank
receiving area. The three points are front left (1),
front right (2), and back center (3). Recall these
three points during the Toilet Tank installation
(see Ill. 5).
6.
Place the tank upside down onto some padding.
Inspect the smaller fill valve nut and larger flush
valve nut for a secure connection (see Ill. 6). Try to
tighten the nuts with your hands. If loose, tighten
the nut hand tight and an additional 1/4 turn for
the smaller fill valve nut and an additional 1/2 turn
for the larger flush valve nut.
Place the tank-to-bowl gasket onto the flush valve
nut. While pressing down, spread the gasket
over the nut until the gasket touches the bottom
of the tank. A slight gap between the tank
bottom and the gasket is allowable.
7. Install and tighten the water supply hose to bottom of fill
valve.(see Ill. 8).
8.
Pick up the tank and carefully guide the brass bolts and
water supply line to align the tank with the bowl. Attach a
metal washer and wing nut to each bolt. Tighten the wing
nuts finger tight and inspect that the tank is level (see Ill. 9).
Once level, tighten the bolts equally until the tank makes
THREE POINTS OF CONTACT with the bowl.
Installation Procedure (continued)
Ill. 3
Ill. 4
Ill. 5
1
Ill. 6
5
Wall
Points of Contact
3
Flush
Valve Nut
Fill
Valve
Nut
Tank to Bowl
Gasket
7/8" Ballcock Thread
HAND TIGHTEN ONLY
Ill. 8
2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cst484cemfg

Table des Matières