filter element manually (do not use tools)
a maximum of a half to three‑quarters of a
turn (7).
3
Maintenance
Draining water from the filter element:
Drain water from the filter element regularly
(once a month) by unscrewing the plug on the
underside. See Drawing 2.
Replacing the Filter Element:
Replace the filter element once a year, or after
every 200 operating hours.
Proceed as follows:
• Shut off the fuel supply (close the valve)
• Drain the fuel from the filter. See Drawing 2
• Unscrew the filter element in the direction
of the arrow. See Drawing 3
4

Technical Data

Type
Maximum capacity
Recommended capacity for normal use
Filter element mesh size
Connections (in‑ and outlet)
Hose pillars for hose, internal
Connector nipples for pipes (external)
Water collector capacity (per filter element)
Weight
Water separator/ Fuel filter WS180 - WS720
• Fill the new filter element with clean fuel (4)
• Lubricate the sealing ring lightly with en‑
gine oil (5)
• Screw on the new filter element in the di‑
rection indicated. When the sealing ring
touches the sealing surface (6), tighten the
filter element by hand (do not use tools) a
maximum of a half to three‑quarters of a
turn (7)
Bleeding:
Most current engines are self‑bleeding. If this is
not the case, you will have to bleed the system
yourself, after draining water or replacing the
filter element.
When the fuel supply pump is fitted in front of
the water separator/fuel filter, the system can
be bled via the hexagon bolt on the top of the
filter.
WS 180
180 l/hour
110 l/hour
40 µm
M14x1.5
ø 8 mm
170 cm
0.7 kg
ENGLISH
WS 720
720 l/hour
440 l/hour
40 µm
M18x1.5
15 mm dia.
3
170 cm
3
1.5 kg
040302.03