Description Of Equipment - Balluff BTL7-S5 Série Notice D'utilisation

Masquer les pouces Voir aussi pour BTL7-S5 Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 71
SCHEDULE
EC TYPE-EXAMINATION CERTIFICATE

DESCRIPTION OF EQUIPMENT

13
The BTL Series Linear Position Transducers are used for linear position measurement feedback
applications. The output signal may be a digital pulse output, an analogue voltage or current output
that corresponds to measured position. The Linear Position Transducers consist of stainless steel
pressure housing and threaded screw on cover, with internal electrical devices rated for voltages
24 Vdc ±20% or in the range 10 Vdc to 30 Vdc, 3 W max for the BTL5 and 10 Vdc to 30 Vdc, 5 W max
for the BTL7. The model code breakdown for the BTL series Linear Position Transducers is as follows:
Key
Q =
Quadrature output
S =
SSI output
T =
Profibus DP output
H =
CANopen output
V =
EtherCAT output
x = 5 or 7
a =
Digital pulse output: I, K, L, M, N, P or R.
b =
Analog output: A, B, C, E or G.
c =
Supply voltage: 1 or 5.
d =
Analog output signal characteristic: 0, 1 or 7 for BTL5 or 00, 01, 02, 03, 04, 05, 06, 07, 10, 11,
70 for BTL7
e =
Quadrature output signal frequency: 0, 1, 2 or 6.
f
=
Quadrature output resolution: 0, 1, 2, 3, 5, 6, 7 or 8.
g =
Quadrature output mode/update rate: 0, 1, 2 or 4.
h =
SSI output signal type, resolution and mode: Any alpha/numeric code (up to 3 digits) not
effecting the Flameproof protection method)
i
BTL7 P/M Interface without DPI/IP interface: 10. BTL7 P/M Interface with DPI/IP interface:
=
11. Blank for BTL5.
j
=
Profibus output software configuration: 1, 2 or 3.
k =
CANbus output software configuration: 1, 2 or 3.
l
=
CANbus output baud rate: 0, 1, 2, 3, 4, 5, 6, 7 or 8.
m = Stroke length in millimeters (Maximums: BTL5 = 5080 & BTL7 = 7620)
n = Interrogation method (if a = "R", otherwise blank): E or I.
o = Recirculation count (if a = "R", otherwise blank): 1 to 16.
q =
Number of magnets or address setting (Any alpha/numeric code not effecting the Flameproof
protection method)
r =
Protocol type (Any alpha/numeric code not effecting the Flameproof protection method)
* = S or M = Special electrical or internal mechanical modifications not affecting scheduled drawings
or the Flame-proof Protection methods and not exceeding 3W for the BTL5 and 5W for the BTL7,
followed by a 4 alpha/numeric combination (may also be left blank)
** = Entry code: TA12 = one modified ½"-14NPT entry and Kp = Certified cable gland with Pre-wired
profibus cable length (two digit code represented in meters): 00 to 50
Note:
The IP68 rating includes a submersion rating of 167 ft (51 m) for 48 hours (TA model codes).
The IP68 rating includes a submersion rating of 167 ft (51 m) for 30 minutes (Kp model codes).
This certificate and its schedules may only be
reproduced in its entirety and without change.
Form 9400 Issue2
BTLx-aci-Mm-J-DEXC- * - ** -no
BTLx-bcd-Mm-J-DEXC- * - **
BTLx-Qcefg-Mm-J-DEXC- * - **
BTLx-Sch-Mm-J-DEXC- * - **
BTLx-Tcj0-Mm-J-DEXC- * - **
BTLx-Hckl-Mm-J-DEXC- * - **
BTL7-Vcqr-Mm-J-DEXC- * - **
Page 2 of 3
Sira
11ATEX1104X
Sira Certification Service
Unit 6, Hawarden Industrial Park,
,
,
Hawarden
CH5 3US
United Kingdom
Tel:
+44 (0) 1244 670 900
Fax:
+44 (0) 1244 539 301