Philips GC7600 Série Mode D'emploi page 12

Masquer les pouces Voir aussi pour GC7600 Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
ENGLISH
12
Problem
The appliance
does not produce
any steam.
The appliance
beeps and less or
no steam comes
out of the iron
when I press the
steam trigger.
The 'ANTI-
CALC cartridge
replacement' light
keeps flashing.
The appliance
produces a loud
pumping sound
(subtle pumping
sound is normal).
The appliance has
switched off.
The iron leaves a
shine or an imprint
on the garment.
4239_000_8623_4_DFU-Luxury_A5_v2.indd 12
Possible cause
There is not enough water
in the water tank.
You have not pressed the
steam trigger.
You have just installed a
new ANTI-CALC cartridge.
The ANTI-CALC cartridge
is not placed properly.
You have to replace the
ANTI-CALC cartridge.
You have to replace the
ANTI-CALC cartridge.
You have just installed a
new ANTI-CALC cartridge.
The water tank is empty.
The ANTI-CALC cartridge
is not in place.
The ANTI-CALC cartridge
is damaged or shows cracks
or hairline cracks.
The safety auto-off function
is activated automatically
when the steam generator
has not been used for
more than 5 minutes.
The surface to be ironed
was uneven, for instance
because you were ironing
over a seam or a fold in the
garment.
Solution
Fill the water tank beyond the MIN indication. Press
and hold the steam trigger until steam comes out. It
may take up to 30 seconds until steam comes out.
Press the steam trigger and keep it pressed when
you iron.
Press and hold the steam trigger for 10 seconds until
steam comes out.
Press down the ANTI-CALC cartridge until it locks
into position.
Replace the ANTI-CALC cartridge (see chapter
'IMPORTANT: Replacing the ANTI-CALC cartridge').
You can also use demineralised water or descaled
water from the IronCare. In that case, you need to
leave the exhausted cartridge in the compartment.
Replace the ANTI-CALC cartridge (see chapter
'IMPORTANT: Replacing the ANTI-CALC cartridge').
You can also use demineralised water or descaled
water from the IronCare. In that case, you need to
leave the exhausted cartridge in the compartment.
Continue to press the steam trigger until the
pumping sound stops and steam comes out of the
soleplate.
Refill the water tank with water and press the steam
trigger until the pumping sound stops and steam
comes out of the soleplate.
Place the ANTI-CALC cartridge (see chapter 'Before
first use - Placing the ANTI-CALC cartridge').
Inspect the ANTI-CALC cartridge thoroughly. If you
see any sign of damage or cracks, no matter how
small, replace the ANTI-CALC cartridge with a new
one.
Press the on/off button to reactivate the steam
generator.
Perfect Care is safe on all garments. The shine or
imprint is not permanent and will disappear when
you wash the garment. Avoid ironing over seams or
folds or you can place a cotton cloth over the area
to be ironed to avoid imprints.
31/03/15 10:24

Publicité

Table des Matières
loading

Table des Matières