Computer instructions for 1910
The supplied computer allows the most convenient training. Every value
relevant to training is displayed in a corresponding window.
From the beginning of the training session, the required time, the current
speed, the approximate calorie consumption and the travelled distance are
displayed. All values are counted from zero upwards.
If you wish to see one value displayed constantly select this with the „F" key.
If you wish to see these values in constant alternation, select the „SCAN"
function. The display then changes from one function to the next at intervals
of approx. 6 seconds.
The computer is switched on by briefly pressing the F- key or simply by
beginning training. The computer begins to register and display all values.
To stop the computer, just stop training. The computer stops all
measurements and retains the last attained values. The last attained values
in the functions TIME, CALORIES and KM are stored for 4 Min. and training
can continue with these values when training is resumed.
The computer switches of automatically approx. 4 minutes after training
is stopped.
Displays:
1. „SPEED" display:
The current speed is displayed in kilometres per hour. The values last attained
by this function are not stored. (Limit of the display: 99.9 km/h.)
2. „TIME" display:
The currently required time is displayed in minutes and seconds. The values
last attained by this function are stored. (Limit of the display: 99.59 minutes.)
3. „DISTANCE" display:
The current status of the travelled distance is displayed. The values last
attained by this function are stored. (Limit of the display: 999,9 km.)
4. „CALORIES" display:
The current status of the consumed calories is displayed. The values last
attained by this function are stored. (Limit of the display: 9999 calories.)
5. „PULSE" display: Only with optionaly Pulsebelt available (un-codet
5,0-5,5 kHz
The current pulse rate is displayed in beats per minute. The values last
attained by this function are not stored. (Limit of both displays: 40 – 240
pulse beats per minute.)
6. „RPM" display:
The current RPM is displayed in revolutions per minute. The values last
attained by this function are not stored. (Limit of the display: 999 RPM.)
7. „SCAN" function:
If this function is selected, the current values of all functions are displayed
successively in a constant sequence approx. every 5 seconds.
Keys:
1. „F" key:
Pressing this key once briefly makes it possible to change from one function
to another, i.e. the respective functions can be selected. The currently
selected function is indicated by an icon in the respective window. If the
key is held longer (approx. 3 seconds), all last attained values are deleted.
2. „E" key (Enter):
By pressing this key once, it is possible to specify values step by step in the
respective functions. For this, the desired function must firstly be selected
using the „F" key.
Holding the key pressed activates faster running. When training begins, the
specified values are then counted down to zero.
Replacing the battery:
1. Open the battery compartment cover and then remove the used Battery.
(If the battery should leak remove them under increased considering that
the battery acid is not into contact with skin come and clean the battery
compartment thoroughly.)
2. Insert the new battery (type (CR2032) 3 V) in the correct order and taking
into account the polarity in the battery compartment and close the battery
cover so that it clicks into place.
3. If the computer does not pick up immediately, the function should Batteries
are removed for 10 seconds and re-inserted.
4. The empty battery properly in accordance with the disposal regulations
disposed of and do not give residual waste.